Interrupting/terminating operation
During breaks
- Determine the approximate duration.
- When cooling down of the material be-
low the minimum paving temperature
must be expected, run the paver fin-
isher empty and create an edge like
the end of a layer.
- Set the drive lever (9) to the center po-
sition.
During extended interruptions
- Drive lever (9) into centre position, RPM speed adjustment (10) to minimum position.
- Switch off ignition.
- Switch off screed heater (system).
- When screed is operated with the optional gas heating system, close the valves of
the bottles.
The screed must be heated up to the correct paving temperature before paving may
be restarted.