Air cleaner (1.4)
The level of air cleaner (1) contamina-
tion depends on the dust content of the
air.
Filter maintenance is needed if the red
service box (3) can be clearly seen on
the maintenance indicator (2) when the
engine is at a standstill.
Dust removal valve
:
- Empty dust removal valve (4) by
pressing the outfeed slot together in
the direction indicated by the arrow.
- Remove any dust deflectors by press-
ing together the upper valve section.
Clean outfeed slot occasionally.
Filter cartridge:
- Open air filter housing (1)
- Take out filter cover (5) and remove fil-
ter cartridge (6).
- Clean filter cartridge or if necessary
replace.
- Cleaning filter cartridge:
- Use dry compressed air (max. 5 bar)
to blow out from inside out,
- in an emergency, carefully tap car-
tridge. Do not damage cartridge
when doing so.
- Check cartridge for damage to filter
paper and gaskets, if necessary re-
place.
Safety cartridge:
- To change, loosen hex nut (8) and pull
out cartridge (7).
- Insert new cartridge, refit hex nut and
tighten.
- Insert filter cartridge (6) and close air
filter housing (1).
After air filter maintenance, always press the reset button on the maintenance indica-
tor (2).
- Observe engine’s operating instructions.
Lufi115.jpg, Lufineu.tif,Lufi2neu.tif,Lufi3neu.tif
1
3
2
2
4
4
5
6
8
7
Summary of Contents for DF 115 C
Page 1: ...Operating instructions 02 01 03 Road Finisher 900 98 06 40 DF 115 C DF 135 C...
Page 2: ......
Page 4: ......
Page 10: ......
Page 12: ......
Page 40: ......
Page 44: ...D 4 D D_DF115_135C_GB fm 4 92 02 01 03 Element2_KC cdr 9 8 12 A 9 A 5 6 7 11 10...
Page 46: ...D 6 D D_DF115_135C_GB fm 6 92 02 01 03 Element2_KC cdr 9 8 12 A 9 A 5 6 7 11 10...
Page 132: ......
Page 178: ......