Conveyor limit switches (88) (left and
right):
The mechanical conveyor limit switches
(88) or the ultrasonic conveyor limit
switches (89) control the material flow at
the respective conveyor half. The con-
veyors should stop when the material
has roughly reached the area below the
auger tube.
This requires that the auger height has
been adjusted correctly (see chapter E).
F114_A1.EPS/Ultra3.EPS
88
89