background image

Notes:

• Technical speci

fi

cations given in this table are supplemental information and cannot give occasion to 

claims.

• Technical speci

fi

cations and package contents are subject to change without notice due to the im- 

provement of SVEN production.

ENG

8

Uninterruptible

Power Supply

Type

Voltage, V
Charging rate, A

7. TECHNICAL SPECIFICATIONS

Apparent power

, V

А

Active power, W
Allowable load of the rated power, %
Overload protection acting, %
Input voltage, V
Output voltage, V
Frequence, Hz (input/output)
Number of phases
Coe

cient of e

ciency (during operation from

batteries), % 

Operation mode
Output waveform 

     

 

 

 

     

Protection 

 

 

     

 

 

 

     

Cooling type
Beeps
Switching time, msec

Battery: plug-in

external (optional)
     

 

 

Temperature conditions, °

С

 

 

Storage temperature, °

С

 

 

Humidity, % 

 

Noise level, dB
Dimensions (W × H × D), mm
Weight, kg 

110

120

~150 – 275

~220 ± 10 %

50 / 50

1

65

continuous, long-lasting

regular sinusoid

against  high voltage/undervoltage, overload,

short circuit, overvoltage

against discharge, overload, short circuit

convective; by fan

low battery charge, overload, error

< 5

non-serviceable leakproof

lead-acid batteries

12
10 

-5 ~ 40

-15 ~ 45

10 ~ 90, without condensation

45

Parameters

Models

Reserve

Home-500

Reserve

Home-800

Reserve

Home-1000

500
300

800
480

1000

600

115 × 165 × 344

140  × 214 × 367

4.6

7.3

9.3

Normal conditions and  AVR
Operation mode from batteries

AVR operation mode

Operation mode from batteries

Summary of Contents for Reserve Home

Page 1: ...www sven fi OPERATION MANUAL Reserve Home Uninterruptible Power Supply...

Page 2: ...e device carefully Make sure there are no accessories left in the box Check up the device for damage if the product was damaged during transportation address the firm which carried out the delivery if...

Page 3: ...ric shock In case of an emergency turn o the UPS and disconnect the power cord from the mains It is strictly prohibited to open the device case there is high voltage inside In case of any problems con...

Page 4: ...providing correct power supply of load at overvoltage undervoltage of the mains without going to the operation mode from batteries The intellectual circuit of battery charging is used in the device wh...

Page 5: ...its value goes beyond its rate g CHECK error indicator h UPS on o button i OVERLOAD overload indicator j buzzer on o button k RS232 RS232 connector l AC Input power cord m Circuit Breaker automatic te...

Page 6: ...on the five segment indicator c every segment displays approx 20 of the battery capacity When the battery is charged completely approx 12 hours all 5 segments of the indicator c must light When the b...

Page 7: ...ns in premises where the device placement is intended must correspond to the norms indicated in the Technical Specifications table The UPS must be stored with batteries full charged Storage conditions...

Page 8: ...teries are discharged greatly 2 Defective batteries 3 Circuit of connecting cables of batteries is open Solution 1 Switch on the switch 2 Switch o the load Press the fuse button If the UPS operation i...

Page 9: ...ode Output waveform Protection Cooling type Beeps Switching time msec Battery plug in external optional Temperature conditions Storage temperature Humidity Noise level dB Dimensions W H D mm Weight kg...

Page 10: ...ve Home 500 800 1000 111024 65 1 105082 75 5 www sven fi 24 5 176 02 02 427447 48310 15 Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandi...