2
THE GENERAL INFORMATION
PURPOSE AND FUNCTIONALITIES
TDR:
To de
fi
ne the distance to place of wave impedance changing for all cable types:
defaults, splices, length, cross - effects, split location.
To mute in high – intensity noise environment. Trace stabilization.
DSP TDR:
To work with a long and problem cable.
Have a logarithmic scale. That allows checking all cable without gaining.
Positioning of measuring cursors on maximum (minimum) value.
Bridge:
Measuring the distance to place of cable insulation reducing.
De
fi
nition of the open-cable or wire reversing location.
Measuring of insulation resistance, loop, ohmic disbalance, electrical capacity of all
cable types.
Color TFT display 800x480.
Multifunctional menu.
PC communication through USB or IRDA.
EXPLOITATION CONDITION
Operational Temperature
from -20 to +50ºC
Relative humidity
to 90% at 30ºC
Atmospheric pressure
from 86 to 106 kPa
CERTIFICATES
The state register
№
17719-07. the certi
fi
cate on the statement of measurement device type
RU.C.34.001.A
№
27301.
TECHNIQUES
TDR
Range of measuring
131, 262, 523, 1046, 2093, 4186,
8371, 16742, 33485, 66970,
133939m
Maximal resolution
0,2 m
Overlapping attenuation
Not less 80 dB
Adjusted amplitude of measuring pulse
6 – 18 V with step 1 V
Measuring pulse duration
16
÷
50000 ns
Number of averaging
2, 4, 8, 16, 32, 64, 128, 256, 512
Range of VF (Velocity Factor ) or CC
1
0,143
÷
1 with step 0,001
1. CC=1/VF