8
the estimation of contact in
fl
uence of the line in which the measuring pulse o n other line in
which the induced signal is observed is got is possible. Also this mode is useful for searching
of wire reversing location (split). The pulse is propagate in the line and reaches a wire reversing
location, which is characterized by a sharp increasing of electromagnetic communication
between the pairs. As a result you can see a characteristic signal on the re
fl
ectogram.
There is new algorithm of muting. During the intense noises it is recommended to turn on the
muting mode. To rise of the trace stability is applied the averaging mode. Growth of averaging
number is cause e stability rising and reducing of the display refreshing speed.
TURNING ON THE TDR
Preliminary choose a cable in Main Menu. The device will adjust on the selected cable
gauges.
If you does not choose a cable – the device will adjust on default cable gauges.
After connect the device to a line through a socket [Rx/Tx] by the measuring cable. Connect a
red cable to a test line. Black wire of cable is standby for frequency measurements (it does not
use during the TDR operating).
TRACE VIEWING