Users Manual Area Scan Cameras svs11002 and svs16000
Page 20
The Terminal Folder
In case you want to make a serial connection to the camera via CameraLink you can type in the
commands listed in Appendix C Of this manual.
The PIV Folder
Activate PIV mode if you need to take 2 images within minimum time
PIV-MODE
SVS11002xTLCPC
SVS11000xTLCPC cameras have the possibility to do 2 images within a extreme short period of
time. This can be done either in the mode „triggered with external exposure“(via pulse width of
the Exync signal) or alternatively „triggered with internal exposure“( set via internal
microcontroller) This is useful for ”particle image velocimetry” ( PIV-Mode).
The time between 2 image acquisitions can be shortened to minimal 30 µs + flash duration time.
The first exposure starts 5 µs after the camera has received the positive slope of Exsync. It ends
120 µs after the negative slope.