Users Manual Area Scan Cameras svs11002 and svs16000
Page 8
2.6 Available Modes of Operation
General:
All modes are set by the serial interface which connects via CameraLink standard cable
.
The default factory setting is
free running
using the internal microcontroller for exposure control:
Mode 0. The Gain of the signal can be adjusted software wise by a factor of 2. Please note that
noise also is amplified.
Higher Gain is possible but not specified!
The Gain default setting is 1.0.
Mode 0: Free running using Microcontroller
In this mode the camera creates all sync signals itself. There is no need to trigger the camera (by
EXSYNC) in order to get data.
The Exposure time can be set by using the serial Interface of
the PC.
The enclosed program allows the user to set the values from about 10.000/sec (1 line
duration) to one frame duration.
Exposure time can be changed online during operation.
Mode 1: Triggered and using Pulse width of Exsync
In this mode the camera is waiting for an external trigger which causes the integration and read
out. The exposure time can be varied by the length of EXSYNC between the high going edge and
the low going edge. The Time settings in the control menu are not activated. This mode is useful
in applications where the light level of the scene changes during operation. A frame to frame
variation is allowed. Trigger can be fed via Framegrabber (if supported) or by TTL(min 5 V) into
on TB 5 connector
(see 2.3)
Mode 2: Triggered and using Microcontroller
The frame rate is determined by the number of Exsync pulses per time. With each positive
transition (going high) the camera will readout a frame. The Exposure time is set as mentioned in
Mode 0. The maximum exposure time is 65535 line durations, Minimum is 1 line duration. Trigger
can be fed via framegrabber (if supported) or by TTL into on TB 5 connector
(see 2.3)
(see 2.3)
Exposure time can be changed online during operation.
Software:
The camera comes with
“Convenient Cam”
program allowing interactive access to above
parameters. This software is available for WIN XP.
The color version will come on request with free software algorithm which will allow processing of
the color image in the PC. This must to be done in order to interpolate the colors for each pixel.
Please note that no responsibility can be taken for the algorithm. It might be necessary to change
the algorithm according to the application.
See chapter 3.7
.
3.0 Operation
3.1 Sensors:
Kodak KAI 11002M/C 4008 x 2672 Pixel Class I for mono/Class 2 for color
and KAI 16000M/C
,
4904 x 3280 Pixel Class I
Note following cosmetic specs for Kodak CCD:
KAI 11002M
Cluster allowed. Cluster may contain up to 20 pixel out of PRNU spec.
20 cluster allowed
Point defects: 1000 pixel dead or out of PRNU spec. (color version up to 2000)
Column defects: Monochrome = 0.
Summary of Contents for CameraLink svs11002
Page 2: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 2 ...
Page 10: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 10 This page is left blank ...
Page 17: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 17 ...
Page 26: ...Users Manual Area Scan Cameras svs11002 and svs16000 Page 26 View on mounting side svs16000 ...