72
A-96.250.321 / 191015
AMI Solicon4
Default Values
10. Default Values
Operation:
Sensors:
Filter Time Const.:..................................................................10 Sec
Hold after Cal.:..................................................................... 300 sec
Relay Contacts
Alarm Relay .................................................. same as in Installation
Relay 1/2 ...................................................... same as in Installation
Input.............................................................. same as in Installation
Logger:
Logger Interval:.............................................................. 30 Minutes
Clear Logger: ................................................................................no
Installation:
Sensors
Sensor Parameters; Cell Constant ...............................0.4000 cm
-1
Sensor Parameters; Temp. corr. ...........................................0.00 °C
Sensor Parameters; Cable length............................................0.0 m
Temp. Compensation; Comp. ...................................................none
Flow; Flow measurement..........................................................none
Conc.: .......................................................................................none
Signal Output 1
Parameter: .................................................................... Conductivity
Current loop: ......................................................................4–20 mA
Function: .................................................................................. linear
Scaling: Range low: ........................................................... 0.000 µS
Scaling: Range high:............................................................ 100 mS
Signal Output 2
Parameter: ....................................................................Temperature
Current loop: .....................................................................4 –20 mA
Function: .................................................................................. linear
Scaling: Range low: ................................................................0.0 °C
Scaling: Range high:.............................................................50.0 °C
Alarm Relay:
Alarm Conductivity:
Alarm high:........................................................................... 300 mS
Alarm low: ............................................................................ 0.00 µS
Hysteresis: .......................................................................... 1.00 mS
Delay:.......................................................................................5 Sec
Sample Flow
(if Flow measurement = yes)
:
Flow Alarm.................................................................................. yes
Alarm high:........................................................................... 50.0 l/h
Alarm low: .............................................................................. 5.0 l/h
Sample Temp:
Alarm High: ............................................................................120 °C
Alarm Low:.................................................................................0 °C