5 Design Guidance
This section describes the
recommended
design practices for successful integration of the
Modem.
5.1 Input Connections
The Swarm Modem utilizes standard 51 mm x 30 mm mPCIe form factors that require an
industry standard connector listed below. All voltage pins need to be connected in such a way to
minimize ground loops, often down by using a via to a power/ground plane. A method of
retaining the Modem is also required, whether it be a retaining clip or screws.
Below are example connectors, retaining clips, and their part numbers. Many vendors and
styles exist from vendors such as DigiKey/Mouser/Newark.
Example Connectors
Example Retaining Clips
JAE:
MM60-52B1-B1-R850
JAE:
MM60-EZH039-B5-R850
TE Connectivity
: 2041119-2
TE Connectivity:
1717832-2
Altium footprints with correct connector/retaining clip spacing can be found in our
.
5.2 Decoupling and Feed-through Capacitors
We
require
a minimum amount of decoupling capacitance in order to reduce/eliminate any high
frequencies from the input supply reaching the Modem input terminals.
Choose Ceramic capacitors rated for 16V or greater, X5R or better
Qty
Size
1
100 nF
1
10 μF
2
100 μF
© 2022 SWARM TECHNOLOGIES
SWARM M138 MODEM PRODUCT MANUAL · REV 1.20 · FEBRUARY 2022
PAGE
21