SWEBO Bioenergy
Manual pellet burner PB20
Rev no.
Date
Page
PBM1:12
2018-01-22
20 (36)
(6.)1 Configuration
Settings for how the heating system is made up
surrounding the automatic lighting control device are
made in the main configuration group.
1.1 Program version
The installed program version is shown under ”Program
version”.
1.2 Connections
Any other equipment connected to the automatic
lighting control device PB 1 is shown under
”Connections”.
1.2.1 Remote panel
”Remote panel” shows whether an extra FT 20 type
front panel is installed on terminals 13-17.
Setting option, Yes or No.
Default setting = No.
1.2.2 Network
”Network” shows whether there is a connection to a
wired computer network via NV 20 device on terminals
13-17.
Setting option, Yes or No.
Default setting = No.
1.3 Start ramp fan
1.3 Start ramp fan
The ramp-up time that is to apply for the fan is set
under ”Start ramp fan” . The ramp-up time is the time it
takes for the fan to achieve the selected speed.
Setting option, 0-40 seconds.
Default setting = 0 seconds.
1.4 Accumulator tank
”Accumulator tank” shows whether there is accumulator
tank lighting. In the event of accumulator tank lighting, 2
temperature sensors must be used. Sensor 1 installed
at the top of the tank and sensor 2 installed at the
bottom of the tank. Connect the sensors according to
the wiring diagram, see 3.3.
Also note that the start temperature (3.2) and stop temp
(3.1) for accumulator tank lighting must be adjusted so
that the burner starts when the upper sensor has
dropped to the start temperature and stops when the
lower sensor has reached the stop temperature.
Note that the start and stop temperatures must not be
the same, around 80 degrees at the bottom and 65
degrees at the top of the tank are appropriate guide
values. Note that the burner should operate at as high
an output as possible during this type of operation and
that both 3.4.x.4 and 3.5 must be in the ”OFF” mode.
Setting option, Yes or No.
Default setting = No.
1.5 Power regulation
1.5 Power regulation
”Power regulation” shows whether power stages should
be selected manually via the front panel or be switched
automatically by the automatic lighting control device
depending on the power output.
Note that if accumulator tank is selected in 1.4
automatic power regulation cannot be selected.
Setting option, Manual or Auto.
Default setting = Manual.
1.6 Available power stages
”Available power stages” shows which power stages
are to be available during automatic power regulation.
1-4 = All power stages available.
2-4 = Power stages 2, 3 and 4 available.
1-3 = Power stages 1, 2 and 3 available.
Setting options, 1-4, 2-4,1-3.
Default setting = 1-4.
1.7 Flame detector
The function of the flame detector is adjusted in the
main group, ”Flame detector”. Here the current flame
detector level is shown.
1.7.1 Firing
1.7.1.1 Level firing
Adjust at which light level the automatic lighting control
device is to detect that a flame is present under ”Level
firing”. The lower value in the display shows the current
light level. Note that the higher the value you select, the
stronger the flame must be for it to be considered
present.
Setting options, 5-95%
Default setting = 12%.
1.7.1.2 Delayed firing
Adjust the time delay from when the light level
exceeded the level set in 1.7.1 until the automatic
lighting control device detects that the flame is present
under ”Delayed Firing”.
Setting option, 1-60 seconds.
Default setting = 10 seconds.
1.7.2 Extinguished
1.7.2.1 Level extinguished
Adjust at which light level the automatic lighting control
device is to detect that the flame has been extinguished
under ”Level extinguished” . The lower value in the
display shows the current light level.
Setting options, 5-95%
Default setting = 10%.
1.7.2.2 Delayed extinguished
Adjust the time delay from when the light level fell
below the level set in 1.7.2.1 until the automatic lighting
control device detects that the flame has been
extinguished under ”Delayed Extinguished”.
Setting option, 1-60 seconds.
Default setting = 30 seconds.
Summary of Contents for PB/20
Page 31: ...SWEBO Bioenergy Manual pellet burner PB20 Rev no Date Page PBM1 12 2018 01 22 31 36 Notes ...
Page 32: ...SWEBO Bioenergy Manual pellet burner PB20 Rev no Date Page PBM1 12 2018 01 22 32 36 Notes ...
Page 33: ...SWEBO Bioenergy Manual pellet burner PB20 Rev no Date Page PBM1 12 2018 01 22 33 36 Notes ...