7.4 Switching off the burner
Switch off the burne
r by pressing the ”On/Off” button until the display shows “Blow cleaning”. The burner will run the fan for
approximately 5-7 minutes to burn off the remaining fuel. If the main current is interrupted, the unburned fuel will remain and
turn to embers.
7.5 Starting the burner after a power cut
The burner will automatically start on the operating settings that applied before the power cut. The first thing the burner does
after a power cut is to blow clean the burner for approximately 5-7 minutes before the first attempt.
If any of the alarm LEDs illuminate after a power cut, the burner had a fault prior to the power cut. (read more under “Faults and
corrective actions”)
8
MAINTENANCE INSTRUCTIONS
Cleaning should be carried out once a week for optimum fuel economy.
NOTE! Store ash in a fireproof container until it has cooled and remember that the burner and boiler can become
extremely hot.
8.1 The boiler
The boiler must be swept clean. Take care to remove soot from all parts of the boiler (between plates).