Safety
WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to
dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel.
This product is designed for Commercial/Industrial use only. It is not intended for use with life support and other designated “critical” devices.
Maximum load must not exceed that shown on the UPS rating label.
The main supply socket or means of isolation must be within 2 meters of the equipment and accessible to the operator. The UPS is designed for
data processing equipment.
The UPS comes with two output power leads with molded connectors. Do not modify the output power leads. Consult dealer if connector does not
match the load socket. UPS must be earthed at all times while in use. Turn UPS off before unplugging it, or the safety earth will be removed.
The 1000VA model is not supplied with an input power lead for connection to the mains supply socket. Use the input mains supply power lead
from you data processing equipment to connect the UPS to the main supply.
CAUTION: The UPS and connected load total earth leakage current must not exceed 3.5 milliamperes If the connected load earth leakage current
is likely to exceed 2.5 milliamperes or you are unsure, then convert the input lead attachment to either a fixed wiring installation or an industrial
plug/socket. This task should be carried out by a competent electrical engineer.
The UPS output supply sockets may electrically live whenever the input power lead is plugged into the mains supply socket. Turning the UPS off
does not electrically isolate the internal parts. To isolate the UPS, turn the UPS off and then isolate it from the main supply.
When installing the UPS or making input and output connections, comply with relevant safety standards.
This equipment complies with requirements of the EMC Directive 89/336/EEC and the published technical standards. Continued compliance
requires installation in accordance with these instructions and the use of manufacturer approved accessories with output cables not exceeding 10
meters (30 ft.) in length. Use a shielded cable for the external communications interface.
Operate UPS only from a properly earth, 50Hz or 60Hz, 220-240 VAC mains supply.
Route power supply leads so they are not walked on or p”ed.
Never block or insert any object into the ventilation holes or other openings. Maintain a minimum clearance of 100mm (4 “es) all around the
UPS for proper airflow and cooling.
Operate the UPS in an indoor environment only, with an ambient temperature range of 0°C to 40°C (32°F to 104°F). Install it in a clean
environment, free from moisture, flammable liquids, gasses, or corrosive substances.
Storing magnetic media on top of the UPS may result in data loss or corruption.
Turn the UPS off and unplug the UPS before cleaning. Use only a soft cloth, never liquid or aerosol cleaners.
This equipment can be operated by individuals without previous training.
CAUTION: The UPS is heavy. Take proper precautions when lifting or moving it.
Please consult the English manual on CD if you require more information.