background image

WISE 

Parasol EX

16

Swegon reserves the right to alter specifications.                           20200901

Summary of Contents for 942428036

Page 1: ...installation 4 Water 6 Air 7 Commissioning 8 Nozzle setting 8 ADC 8 Connections 9 WISE Parasol EX with factory fitted components 9 Factory fitted components as an option 9 LED Explanation 9 Use 10 Tr...

Page 2: ...Electrical data It is not permissible to insert foreign objects into the product s contactor connections or ventilation openings risk for short circuiting 24 V isolation transformer to be connected sh...

Page 3: ...te the height measure ment H increases by 12 mm Weight WISE Parasol EX 690 Size Type Dry weight kg Water volume l cooling heating 690 690 A 22 8 1 1 690 690 B 24 0 1 1 0 2 690 PF 690 A 24 2 1 1 690 PF...

Page 4: ...WISE Parasol EX 4 Swegon reserves the right to alter specifications 20200901 Installation base module Suspension A B A1 B1 B2 A2 B Surface mounted installation A Suspended installation...

Page 5: ...5 20200901 Swegon reserves the right to alter specifications WISE Parasol EX A4 B4 B5 M8 A5 A6 160 PF 125 MF HF A3 B3...

Page 6: ...sol EX A only Cooling Return Plain pipe 12 x 1 0 mm Supply pipe Plain pipe 12 x 1 0 mm WISE Parasol EX B Cooling Heating Return Plain pipe 12 x 1 0 mm Supply pipe Plain pipe 12 x 1 0 mm utv ndig g nga...

Page 7: ...WISE Parasol EX 690 HF 125 WISE Parasol EX 690 PF 160 WISE Parasol EX 1290 HF 125 WISE Parasol EX 1290 PF 160 Air Water Air 1 2 4 3 Air connection on side 2 standard Base module with mounted valve ki...

Page 8: ...n shape WISE Parasol EX is a part of the WISE system that demand controls both air and water on a room level and guarantees the highest level of indoor climate with minimum energy consumption This mea...

Page 9: ...g on the pipes Supplied but requires easy installation on the face plate Cable for connection of WISE SMB is prefitted on the base module and connected on WISE CU but requires the cable to be connecte...

Page 10: ...ct should be cleaned twice a year by vacuu ming the coil to remove loose dust In fibre dense environments a more frequent interval is recommended A simple visual inspection of connections is recommend...

Page 11: ...ectromagnetic compatibility EMC Generic standards Emission standard for residential commercial and light industrial environments EN 300 328 V1 9 2 V1 9 1 V1 8 1 Electromagnetic compatibility and Radio...

Page 12: ...WISE Parasol EX 12 Swegon reserves the right to alter specifications 20200901 Installation design module A7 B6 A8 B7 TORX T 25 1 x 8 A9 B8 A10 B9 Click...

Page 13: ...13 20200901 Swegon reserves the right to alter specifications WISE Parasol EX A11 B10 A13 B12 A14 B13 Click A12 B11...

Page 14: ...WISE Parasol EX 14 Swegon reserves the right to alter specifications 20200901 A15 B14 A16 B15...

Page 15: ...15 20200901 Swegon reserves the right to alter specifications WISE Parasol EX Maintenance 1 2 4 5 7 7 3 6 Click Click Opens side A or B A B...

Page 16: ...WISE Parasol EX 16 Swegon reserves the right to alter specifications 20200901...

Reviews: