General
7
[ G ]
Product spec sheet
– Directive 2009/125/EC
Supplier
bluMartin GmbH
Ventilation model
freeAir 100
– single room (non-ducted)
freeAir 100
– multiple room (ducted)
SEC-Class
Single room:
A+; -42.4 kWh/a m
2
Multiple room:
A+; -42.7 kWh/a m
2
Model-Type
Bidirectional residential ventilation unit
Drive-Type
Variable speed drive
Heat recovery
Recuperative
Thermal efficiency
87 %
Maximum flow rate
100 m
3
/h
Maximum power input
40 W
Sound power level
Single room:
70 m
3
/h
→ 48 dB (A); 20 m
3
/h
→ 28 dB (A)
Multi room:
70 m
3
/h
→ 47 dB (A); 20 m
3
/h
→ 23 dB (A)
(with premium cover 12 dB less)
Reference flow rate
70 m
3
/h
Reference pressure difference
65 Pa
Specific power input
Single room:
0.22 W/m
3
h
Multi room:
0.24 W/m
3
h
Control factor
0.65 (local demand control)
Internal leakage
1.7 % (at 100 m
3
/h and 50 Pa)
External leakage
3.2 % (at 100 m
3
/h and 100 Pa)
Mixing rate
3.5 %
Visual filter warning
Red LED left and right side of device (dirty filters result
in diminished air flow as well as over or under pressure)
Internet address
Sensitivity to pressure variations 3.0 %
Air tightness
3.2 m
3
/h (at 100 Pa)
Wessling, July 8th, 2020
Bernhard Martin
Summary of Contents for bluMartin freeAir 100
Page 1: ...Manual G General O Operation I Installation S Service ...
Page 20: ...Installation Bare Brickwork Set 18 I Drawings ...
Page 21: ...Installation Bare Brickwork Set 19 I ...
Page 23: ...Installation Bare Brickwork Set 21 I ...
Page 24: ...Installation Bare Brickwork Set 22 I ...
Page 25: ...Installation Bare Brickwork Set 23 I ...
Page 26: ...Installation Bare Brickwork Set 24 I ...
Page 27: ...Installation Bare Brickwork Set 25 I ...
Page 28: ...Installation Bare Brickwork Set 26 I ...
Page 59: ...Service S 57 For troubleshooting visit the website www bluMartin de freeair support ...