7
Manufacturer reserves the right to alter specifications
Varning
The unit and the ventilation system must be
installed by a qualified person in accordance
with local rules and regulations.
.
Installation
The unit is to replace depleted and humid air
from the property to the new fresh air from
outside. To recover heat from the used air and
preheat outside air before it is blown into the
property.
Unpacking
Check that all ordered equipment are included
before installation.
If the unit is not started up directly after installa-
tion, ducts shall be covered with an airtight lid,
the unit must be kept protected from dust and
moisture.
Taken into account
Do not connect the dryer or cooker hood to the
vent system.
Duct connections / duct ends should be cove-
red during storage and installation.
Varning
There may be hidden sharp edges, use gloves!
The unit is heavy!
DO NOT lift the duct connections!
Installation
Description of the flow direction
V90 and V90EL comes in left-hand version. Unit
can be installed in the right design for easier
installation and connection of the duct system.
How you change the air direction is described
on page 11, we advise against installing V90 /
V90EL in right hand when the unit is mounted
vertically, as this can lead to condensation in the
heat exchanger.
Extract Exhaust
Supply
Outdoor