3

20200910                          Swegon reserves the right to alter specifications.

REACT 

P

Rectangular design 

Size WxH (mm)

Tube length 

(meters)

Weight (kg)

Motor

Torque (Nm)

200 x 200

2

7.2

10

300 x 200

4

8.4

10

400 x 200

4

9.9

10

500 x 200

6

11.4

10

600 x 200

6

12.9

10

700 x 200

8

14.4

10

800 x 200

8

15.4

10

1000 x 200

12

18.4

10

300 x 300

4

10.9

10

400 x 300

4

12.4

10

500 x 300

6

13.9

10

600 x 300

6

15.4

10

700 x 300

8

16.8

10

800 x 300

8

18.4

10

1000 x 300

12

21.4

10

400 x 400

4

14.0

10

500 x 400

6

16.0

10

600 x 400

6

17.4

10

700 x 400

8

19.6

10

800 x 400

8

21.1

10

1000 x 400

12

24.2

10

1200 x 400

12

27.2

15

1400 x 400

16

30.3

15

1600 x 400

16

33.3

15

500 x 500

6

18.5

10

600 x 500

6

20.5

10

700 x 500

8

22.6

10

800 x 500

8

24.6

10

1000 x 500

12

28.6

15

1200 x 500

12

32.7

15

1400 x 500

16

36.8

15

1600 x 500

16

40.8

15

600 x 600

6

22.7

10

700 x 600

8

24.8

10

800 x 600

8

26.8

15

1000 x 600

12

30.9

15

1200 x 600

12

35.0

15

1400 x 600

16

39.2

15

1600 x 600

16

43.3

15

700 x 700

8

27.6

15

800 x 700

8

30.3

15

1000 x 700

12

34.9

15

1200 x 700

12

40.6

15

1400 x 700

16

45.7

15

 

H

B

104

20

220

20

20

Figure 6. Dimensions (mm), REACT P rectangular.

 

Installation – rectangular design

Dimension B in the figure and table below is found in the 
table “Rectangular design” to the left. 

NOTE! Damper spindles must be installed horizontally.

Straight section before REACT P in rectangular ducts

Type of disruption

E

One 90° bend

E = 2 x B

T piece

E = 2 x B

Figure 4. Straight section requirements and spacing, rectangular 
ducts.

Figure 5. Straight duct section and spacing requirements, rec-
tangular REACT P and sound attenuator with baffle. Installation 
with a straight duct section applies to both the supply air and the 
extract air.

Straight duct section before/after REACT P – sound 

attenuator with baffle

3

2

1.  = Rectangular REACT P.
2.  = Straight duct 

2xB.

3.   = Sound attenuator with baffle.

1. Controller/Actuator always on the side of the rectangular damper.
E = Straight section.

W = Width, duct.

H = Height, duct.

1

Spacing at least 5xW

Spacing at least 5xW

Spacing at least 5xW

Straight duct section 

at least 2xW

Summary of Contents for REACT Pa

Page 1: ...n the damper blade rotates The product s actuator is equipped with a release button that permits manual control of the damper blade always ensure this is activated before working on the internal parts of the damper If the product is equipped with a spring return actuator there is no release button manual control is performed using the sup plied hex key where the damper blade is cranked to the requ...

Page 2: ...e frame of the building on each side of REACT P Figure 2 Spacing requirements circular ducts quantity Ø before and after the product 1 At least 5 x Ø after the damper supply air 2 At least 5 x Ø before the damper extract air 3 Examples of how spacing can be measured 4 Installation of measurement toppings 1 2 E 1 REACT P 2 FSR Clamp 80 3 6 0 Circular design Size ØD mm Tube length meters A mm B mm C...

Page 3: ...9 2 15 1600 x 600 16 43 3 15 700 x 700 8 27 6 15 800 x 700 8 30 3 15 1000 x 700 12 34 9 15 1200 x 700 12 40 6 15 1400 x 700 16 45 7 15 H B 104 20 220 20 20 Figure 6 Dimensions mm REACT P rectangular Installation rectangular design Dimension B in the figure and table below is found in the table Rectangular design to the left NOTE Damper spindles must be installed horizontally Straight section befor...

Page 4: ...n 0 10 and 2 10 V via the edit wheel Pnom Pnom Pres Unit Pres Unit Pmin Pmin Pmax Pmax T Test est Mode Mode Adr Adr Pa Test inH O 10 3 x P n o m P n o m P r e s U n it P r e s U n it P m in P m in P m a x P m a x T T e s t e s t M o d e M o d e A d r A d r P a T e s t in H O 1 0 3 x Addr Used for Modbus for particulars on how to use Modbus see next page Pnom Pnom Pres Unit Pres Unit Pmin Pmin Pmax...

Page 5: ... 0 100 Addr Used for selecting communication settings for Modbus See table below Pnom Used for setting response delay for the Modbus communication see separate documents How to use Modbus Modbus tables are available in a separate document REACT Modbus m Display number EEPROM value Communication rate Parity Stop bits 13 0 1200 None 2 23 1 1200 Even 1 33 2 1200 Odd 1 4 3 2400 None 2 5 4 2400 Even 1 ...

Page 6: ...anized sheet steel Z275 Disposal Waste must be handled according to local regulations Product warranty The product warranty or service agreement will not be valid will not be extended if 1 the product is repaired modified or changed unless such repair modification or change has been approved by Swegon AB or 2 the serial number on the product has been made illegible or is missing Trouble shooting T...

Page 7: ... you know the value of the current pressure Pact Calculation of the current actual value U when you know the value of the current pressure Pact Key to formulas above Y control signal in V DC U actual value signal in V DC Pact current air pressure in Pa inH2 O 10 3 Pmin set min pressure in Pa inH2 O 10 3 Pmax set max pressure in Pa inH2 O 10 3 Performance checks Replacing the damper motor Figure 11...

Page 8: ... EU EMC and 2011 65 EU RoHS2 The following standards have been observed EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk mitigation EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 Generic standards EN 60730 1 2011 Automatic electrical controls for household and similar use Part 1 Generic standards EN 61000 6 2 2007 Electromagn...

Reviews:

Related manuals for REACT Pa