Application area

The product is a variable flow damper, constant flow damper or a 
constant pressure damper with integrated radio transmitter designed 
for comfort ventilation indoors within Swegon’s system for demand-
controlled ventilation WISE. The product is used to regulate supply or 
extract air flow, alternatively constant pressure hold a static pressure in 
the ventilation duct. 

The product may not be used for anything other than its intended use.

General

Read through the entire instructions for use before you install/
use the product and save the instructions for future reference. It 
is not permissible to make changes or modify this product other 
than those specified in this document.

The packaging contains the following items:

1 x WISE Damper

1 x Instructions for use

Protective equipment

Always use appropriate personal protective equipment for the 
work in question, in the form of gloves, respirators and protec-
tive glasses during handling, installation, cleaning and service/
maintenance.

Electrical safety

Permitted voltage, see “Electrical data”.
It is not permissible to insert foreign objects into the product’s contac-
tor connections or the electronics's ventilation openings; risk for short 

circuiting.
24 V isolation transformer to be connected should comply 
with the provisions of IEC 61558-1.

Cable sizing must be carried out for cabling between the product and 
the power supply source.
Disconnect the power supply when working on products that are not 
required to run in production.
Always follow the local/national rules for who shall be permitted to 
carry out this type of electrical installation.

If the product is equipped with a spring return actuator there is no 
release button, manual control is performed using the supplied hex key 
where the damper blade is cranked to the required position and then 
locked. Do not forget to disable the lock after working on it.

Other risk

When the product is voltage fed, the damper will be either open 
or close and there can be a certain risk for pinch injuries, for 
example, on the fingers if these are placed between the damper 
blade and ventilation duct when the damper blade rotates. 
The product’s actuator is equipped with a release button that 
permits manual control of the damper blade, always ensure this 
is activated before working on the internal parts of the damper. 

Handling

•  Always use appropriate transport and lifting devices when the prod-

uct is to be handled to reduce ergonomic loads. 

•  The product must be handled with care.
•  It is not permissible to carry the product by the measuring tube.

Installation

•  Moist, cold and aggressive environments must be avoided.
•  Avoid installing the product near a heat source.
•  Assemble the product according to applicable industry regulations.
•  Install the product so that it is not accessible by unauthorized per-

sons, for example above a suspended ceiling.

•  Install the product for easy access during service/maintenance.
•  Supplement the duct system with a cleaning hatch in the vicinity of 

the product to facilitate cleaning.

•  If the product is mounted above a fixed ceiling, the inspection hatch 

must be located so that the product is accessible for inspection.

•  If the product is mounted so that it is possible to gain access to the 

inside of the product, it must be supplemented with appropriate 
protection, for example, a ventilation unit.

•  If the product is mounted in cold areas, the whole product must be 

insulated on the outside against condensation.

•  For installation, the accessory FSR is recommended.
•  The product can be installed position-independent.
•  It is recommended to mount the product so that the product’s cover 

is visible from the floor.

•  The product must be laid down prior to installation so that it cannot 

fall over.

•  Check to make sure that the product does not have any visible 

defects.

•  Check that the product is properly secured after it has been 

installed.

•  Use the product’s eyes to secure the cables with cable ties.
•  Check that all cables are properly secured in place after installation.
•  Check that the cover is properly mounted in place.

Summary of Contents for WISE Damper a

Page 1: ...equired position and then locked Do not forget to disable the lock after working on it Other risk When the product is voltage fed the damper will be either open or close and there can be a certain ris...

Page 2: ...91 1768 5 315 600 610 10 5 2 0 10 6 2 50 180 780 2808 8 400 830 850 10 8 0 0 10 9 0 87 314 1257 4526 13 500 830 850 10 9 9 0 10 10 9 135 486 1964 7071 20 630 915 935 15 13 5 0 20 14 5 187 674 3118 112...

Page 3: ...000 14400 40 1000 x 500 15 28 6 20 30 6 429 1545 5000 18000 50 1200 x 500 15 32 7 20 34 6 514 1851 6000 21600 60 1400 x 500 15 36 8 20 38 7 600 2160 7000 25200 70 1600 x 500 15 40 8 20 42 8 686 2470 8...

Page 4: ...be blue Pressure tube red 24 V DC U Ground Y Figure 9 WISE Damper connections Connections LED Explanation Not paired Colour Type Energized White Permanent Selected in TuneWISE White Flashing fast Prep...

Page 5: ...sor does not hang outside the product Check that the VOC sensor is connected to the right input Cleaning Ideally the product should be cleaned in connection with the cleaning of the rest of the ventil...