The alarm light is on
Over heat
protection.
Over welding
current.
Induce the welding current
output
Arc blow
Airflow disturbance.
Use the shelter from airow.
Adjust the electrode angle.
Change the electrode
The electrode eccentricity.
Magnetic effect.
Incline the electrode to the
opposite way of the
magnetic blow.
Change the position of earth
clamp or add earth cable in
the two side of workpiece.
Use the short arc operation
DEFAULT
CAUSE
PREVENTION