4.1) INSTALLATION CONDITION
4.1.1) Temperatures
1) When machine in operation: 15 ~ 40
℃
(59 ~ 104
℉
)
2) When machine is idle:
-
25 ~ 55
℃
(
-
13 ~ 131
℉
)
4.1.2) Humidity
1) relative humidity : 45~85%
4.1.3) Grounding
Ensure the electricity is properly grounded.
4.1.4) Surrounding environment
Close any doors or windows near the machine to prevent direct sunlight, dust, and humidity.
4.1.5) Place of installation
Foundation (floor) under the machine must be sufficiently strong and flat concrete to support the weight of the
machine.
4.1.6) Industrial environment classification
Installation and use of the machine must be performed in an industrial area.
(SWF machines should be used in Class A environment)
Meet the conditions described in the manual when installing the machine. Failure to follow the
directions may result in unexpected machine malfunctions.
CAUTION
1) Do not let moisture drops on the machine.
2) Provide air conditioning to control humidity and to prevent dust and corrosion.
CAUTION
Ensure properly grounding of the machine to avoid the possibility of electric shock. Use three-
wire grounding (grounding resistance below 100 ohms).
CAUTION