Electrical Systems
41
Fault
3.4 FAULT TABLE
Possible Cause
Proposed Fix
No 240 volt output
No 12 volt output
Connecting lead between the site and Leisure Vehicle
not connected
RCD switched off
RCD not operating correctly
MCB switched off
No or deficient supply from site
Other fault
No 240v supply
Charger not switched on
Battery not connected and / or charged
Power switch on control panel not switched to ON
Battery flat / Battery fuse blown
Fuse blown
Check and connect lead as per 3.2.C
Check also input connector at the base of the PSU
2007
Reset RCD as per 3.2.D
Check supply polarity; if the RCD continues to fail
contact your Dealer, as there is probably a wiring or
equipment fault.
Reset MCB by switching OFF (down position) then
back ON (up position), if the MCB continues to fail
contact your Dealer, as there is probably a wiring or
equipment fault.
Contact site Warden for assistance
Contact your Dealer
Check all above
Switch charger switch on (I) position, switch will
illuminate
Install charged battery as per 3.3.B
Turn power on at control panel
Recharge battery, check fuses, check charging voltage
is present at battery
Check all fuses are intact and the correct value fuse is
installed as per fuse table shown in 3.5
Summary of Contents for Bessacarr 2006
Page 2: ......
Page 4: ......
Page 5: ...THE MOTORHOME CODE Code of Conduct 2 The Country Code 4 The Coastal Code 4...
Page 16: ...12...
Page 17: ...EN ROUTE Spare Wheel Removal 14...
Page 19: ...SAFETY SECURITY Fire 16 Ventilation 16 Escape Paths 16 Children 16 Security 16...
Page 22: ...18...
Page 23: ...ARRIVAL AT SITE Positioning the Motorhome 20...
Page 29: ...Connecting Services 25 Typical gas schematic drawing...
Page 105: ...Equipment Details 101 Fig 1 Front Plate Fig 2 Connection Fig 3 Wiring Diagram...
Page 116: ...112...
Page 120: ...116 Notes...