66
Electrical operation 230 V
The green indicator lamp on the control
panel illuminates when the unit is switched
on, the yellow indicator lamp on the power
selector switch does not illuminate and the
heating does not become warm.
- No supply voltage.
- Device fuse defective.
- Overheating switch has triggered.
- Check 230 V supply voltage and fuses.
- Check device fuse (see Maintenance).
- Reset overheating switch (see
Maintenance).
FAULT
CAUSE
RECTIFICATION