Equipment Details
Automatic Energy Selection
“AUTO”-operation
RM7XX5 L - models are equipped with an
“AUTO”-MATIC function.
Manual operation is possible at any time.
Explanations:
Upon switching on, the electronics
automatically select one of the three
possible energy types: 230V - 12V - liquid
gas. The control electronics automatically
ensure that the refrigerator is supplied with
the optimum source of energy in each
respective case.
Priority
1.) Solar (12V DC)
2.) 230V AC
3.) 12V DC
4.) Liquid gas
The selected energy
is displayed by the
corresponding LED
(i.e. 230V).
230 V - operation
If sufficient supply voltage is available (more
than 200V), this power source is selected as
the first option ( no solar-system installed).
12 V - operation
12V operation should only be selected while
the vehicle motor is running or there is
sufficient voltage available from the solar
system. This can be detected from the D+
connection of the alternator to the
electronics, or from the respective signal on
the solar charge regulator.
Gas operation
Gas operation is selected in the following
circumstances:
•
No supply voltage available.
•
The vehicle engine is not running.
•
Supply voltage less than 200V
REFUELLING STOP
In order to prevent unintended switching to
gas operation during refueling, the electronic
system starts gas operation of the
refrigerator, after the motor has been turned
off for 15mins. During this time the appliance
is in stand-by operation mode and only the
"AUTO" LED lights up.
The use of naked flames is prohibited in
petrol station environments. If the
refuelling stop lasts longer than 15mins,
the refrigerator should be
switched off at the main switch (A), or
switched over to another energy type.
Gas faults
(RM 76x1 and RM 76x5)
If gas faults occur
the operating LED “C”
flashes yellow.
Remedies:
Set the energy selector switch (A) to
position “OFF”.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to “on” The
ignition starts again.
80
1. Set energy selection
switch (A) to position
AUTO” .
The LED "AUTO"
illuminates.
Summary of Contents for Bessacarr 2006
Page 2: ......
Page 4: ......
Page 5: ...THE MOTORHOME CODE Code of Conduct 2 The Country Code 4 The Coastal Code 4...
Page 16: ...12...
Page 17: ...EN ROUTE Spare Wheel Removal 14...
Page 19: ...SAFETY SECURITY Fire 16 Ventilation 16 Escape Paths 16 Children 16 Security 16...
Page 22: ...18...
Page 23: ...ARRIVAL AT SITE Positioning the Motorhome 20...
Page 29: ...Connecting Services 25 Typical gas schematic drawing...
Page 105: ...Equipment Details 101 Fig 1 Front Plate Fig 2 Connection Fig 3 Wiring Diagram...
Page 116: ...112...
Page 120: ...116 Notes...