a = Rotary switch "On" "Gas operation"
b = Rotary switch "Off'"
c = Rotary knob for temperature
selection (illuminated by green
lamp "Operation")
d = Red indicator lamp "Failure"
Equipment Details
51
1. Check that the safety/drain valve in the
cold-water intake is closed. Lever should
be in the horizontal position, position (e).
2. Open the hot tap in the bathroom or
kitchen with pre-selecting mixing taps or
single lever fittings set to hot.
3. Switch on power for water pump (main
switch or pump switch). Leave the tap
open to let air escape while the water
heater is filling. The heater is filled when
water flows out of the tap.
Residues of frozen water can prevent
filling if there is a frost. The water heater
can be defrosted by switching on the
heater for a short period (max 2 mins).
Frozen pipes can be defrosted by heating
the room.
Note:
If just the cold water system is being
used, without water heater, the heater tank
is also filled up with water. In order to avoid
damage through frost, the water contents
must be drained by actuating the
safety/drain valve, also when the heater has
not been used. As an alternative, two shut-
off valves, resistant to hot water, can be
fitted in front of the cold and hot water
connection.
Draining the water heater
1. Disconnect power for water pump (main
switch or pump switch).
2. Open hot water taps in bathroom and
kitchen.
3. Open safety/drain valve: Lever in vertical
position, position (f).
4. The water heater is now drained directly
to the outside via the safety/drain valve.
Check that the water contents have been
completely drained (10 litres).
Gas operating instructions
Attention:
Never operate the water heater
without water in it!
If the wall cowl is positioned close to an
opening window (or hatch) - in particular
directly under it - it must remain closed
when the water heater is in use (see
warning plate).
1. Remove cowl cover.
2. Open gas cylinder and open quick-acting
valve in the gas supply line.
3. Select required water temperature at
rotary knob (c) infinitely variable from
approx. 30° to 70°c.
4. Switch on water heater at the rotary
switch (a) on the control panel, green
indicator lamp "Operation" lights up.
5. If there is air in the gas supply line, it may
take up to a minute before the gas is
available for combustion. If the appliance
switches to "Failure" during this period,
switch off the appliance - wait 5 minutes -
and switch on again!
Summary of Contents for 2005 MH
Page 1: ...Quality with Style Swift Motorhomes Owner s Handbook...
Page 4: ...THE MOTORHOME CODE Code of Conduct 2 The Country Code 4 The Coastal Code 4...
Page 14: ...EN ROUTE Spare Wheel Removal 12...
Page 16: ...SAFETY SECURITY Fire 14 Ventilation 14 Escape Paths 14 Children 14 Security 14...
Page 19: ...ARRIVAL AT SITE Positioning the Motorhome 18...
Page 25: ...Connecting Services 23 Typical gas schematic drawing...
Page 97: ...Equipment Details 95 Fig 1 Front Plate Fig 2 Connection Fig 3 Wiring Diagram...