8

 
 
 
 
   

 
 
 
 
 

 

 

 

 

 

 

 

DIGITAL PHOTOGRAPHY 

The M3501CL-DGL and M3503CL-4DGL models feature a built-in 1280 X 
1024 pixel digital camera to capture still images or video clips on to a 
computer.    In order to use the camera, the software must first be 
installed on a computer.    The minimum computer requirements to use 
the camera is having an available USB 2.0 port, Windows XP, Vista or Mac 
OS X operating system installed on the computer, 512MB of RAM, 1GB free 
hard drive space and 1Ghz CPU.   

Instructions on how to install and use 

the software is included on the software CD that was packaged with 
the M3501CL-DGL and M3503CL-4DGL microscopes.

   

 

 

 

 

 

Summary of Contents for M3500 SERIES

Page 1: ...CROSCOPE The Swift M3500 Series microscope is considered to be the most Student proof microscope on the market It is an instrument of optical and mechanical precision and will perform satisfactorily w...

Page 2: ...age drift CONDENSER the condenser is mounted in the stage and it is used in conjunction with the iris diaphragm The function of the condenser is to provide full illumination to the specimen plane and...

Page 3: ...ide in place allowing the user to move the slide on any x y axis through the manipulation of two control knobs or a co axial control mechanism NOSEPIECE the revolving turret that holds the objective l...

Page 4: ...COVER GLASS Thin glass cut in circles rectangles or squares for covering the specimen usually a thickness of 0 15 to 0 I7mm The majority of specimens should be protected by a cover glass and must be c...

Page 5: ...esolving power is directly proportional to the numerical aperture of the optical system WORKING DISTANCE the distance from the lens of the objective to the cover slip on the slide when the specimen is...

Page 6: ...ification of 400X or lower However at a magnification of 1 000X and above refraction becomes problematic This problem is reduced significantly by placing a thin layer of very clear viscous oil between...

Page 7: ...100XRD objective requires an iris diaphragm for brightfield oil immersion microscopy HOW TO USE THE POINTMASTER EYEPIECE RETICLE Swift s patented POINTMASTER eyepiece reticle which is installed in the...

Page 8: ...ware must first be installed on a computer The minimum computer requirements to use the camera is having an available USB 2 0 port Windows XP Vista or Mac OS X operating system installed on the comput...

Page 9: ...e microscope is not in use CLEANING The front lens of the objectives particularly the 40XRD and 100XRD should be cleaned after use First brush with a soft camel hair brush or blown off with clean oil...

Page 10: ...ay corrode your microscope Also be sure that the objectives are placed in the lowest possible position and the rotating head is turned inward and not protruding from the base Microscopes with mechanic...

Page 11: ...s electrical cord from the electrical socket and remove any slides on the stage Use the small allen wrench 09mm that was included with the microscope to loosen the set screws that hold the black illu...

Page 12: ...e enough Slowly open the diaphragm to increase the size of the opening allowing for additional illumination E PROBLEM Once the specimen is in focus it moves out of focus CORRECTION Gravity is causing...