I. Specifications

 

Model 

SW350T 

Head 

360° rotatable Trinocular Siedentopf 

Inclination 

30° 

Eyepieces 

Wide-field 10X and 25X pairs 

Interpupillary distance  48-75mm 

Diopter adjustment 

On left tube, +/-5dp 

Nosepiece 

Quadruple revolving 

Objectives 

Achromatic 
4X, NA 0.1, working distance 37.5mm 
10X, NA 0.25, working distance 7.35mm 
40X(Spring), NA 0.65, working distance 0.29mm 
100X (Spring, Oil), NA 1.25, working distance 0.18mm  

Magnifications 

40X, 100X, 250X, 400X, 1000X and 2500X  

Stage 

Double-layered mechanical stage with slide holder 

Stage size 

130mmx130mm 

Stage X-Y range 

70mmx30mm 

Upper limit stop 

Rack stop preset but adjustable 

Condenser 

NA 1.25 with iris diaphragm 

Focusing 

Coaxial coarse and fine focusing system 

Illumination 

Built-in 1W LED transmitted illumination with intensity control 

Power 

110-240V AC adapter (included) 

 

 

Summary of Contents for SW350T

Page 1: ...User Guide SW350T...

Page 2: ...s of your new microscope and help you begin to use it For more information about our microscopes or customer service requests www swiftoptical com Table of Contents I Specifications 2 II Parts of the...

Page 3: ...ce 7 35mm 40X Spring NA 0 65 working distance 0 29mm 100X Spring Oil NA 1 25 working distance 0 18mm Magnifications 40X 100X 250X 400X 1000X and 2500X Stage Double layered mechanical stage with slide...

Page 4: ...e to insert the eyepiece adapter into the trinocular camera port on the top of the microscope and place either a third eyepiece into it or mount an eyepiece camera not included Locate the power adapte...

Page 5: ...lder once the specimen is in focus Increase magnification by rotating the nosepiece clockwise to a higher magnification objective taking care not to strike the slide with the objective as doing so may...

Page 6: ...pter to adjust the adapter height position and resulting parfocality VI Caring for your microscope As with any quality instrument your microscope should be stored in a cool dry place Use the dust cove...

Page 7: ...d too far Open the iris aperture wider Visual field is blurry or dirty Dirty objective or eyepiece lens Clean with compressed air or soft brush The slide is dirty Clean the slide with glass cleaner Ey...

Page 8: ...t Adjust the safety rack stop to stop the stage farther from the objectives Image won t come into focus when using a higher powered objective Slide is upside down Flip the slide over so the cover slip...

Page 9: ...equired Buyers are responsible for shipping to and from our warehouse for warranty services The warranty does not cover damages resulting from normal wear and tear abuse or unauthorized repairs For mo...