Symptom
Cause
Measure
Water Leakage
Joints are
defective
Close the main valve connected to the
tap and turn off power. Contact service
center.
Bad taste or odor
is present
Carbon filter is
reaching its
lifespan
Replace Carbon filter and drain at least
10 L of water before use.
Contaminated
water tank
Clean water tank.
Stagnant water Drain the water in the tank 2 ~ 3 times
before use.
White bubbles in
purified water
Air bubbles
formed due to
microfiltration.
If they do not disappear after a while,