background image

FCC STATEMENT:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could 
void the user’s authority to operate the equipment.

RSS 210 WARNING STATEMENT:

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: 

(1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. 
L’exploitation est autorisée aux deux conditions suivantes : 

(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en

compromettre le fonctionnement.

The internal battery is not replaceable. Disposal of a battery into fire or a hot oven, leaving the battery in high  
temperature surrounding environment or mechanically crushing or cutting a battery can result in an explosion  
or leakage of flammable liquid or gas. Do not ingest battery, Chemical burn Hazard. This product contains a  
coin cell battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can  
lead to death. Keep new and used batteries away from children. If the battery compartment does not close  
securely stop using the product and keep away from children. If you think batteries might have been  
swallowed or placed inside any part of the body, seek immediate medical attention.

© 2020 American Thermal Instruments, Inc. All Rights Reserved All other trademarks are the properties of their respective owners.

switrace.com | +41 91 646 18 74 | info@switrace.com

20

 

ATI20-075 LOG-IC® BT & BT RH Users Guide

in partnership with American Thermal Instruments

Summary of Contents for LOG-IC 360 BT

Page 1: ...endrisio Switzerland 2020 American Thermal Instruments Inc All Rights Reserved All other trademarks are the properties of their respective owners in partnership with Revolutionize Your Cold Chain Blue...

Page 2: ...CREATING AND USING A PROFILE TO A BATCH OR GROUP 12 Creating a Batch and Deploying a Profile 12 Creating a Group and Deploying a Profile 12 UTILIZING USER MARKS 13 User Marks 13 READING THE DISPLAY O...

Page 3: ...evice home screen TURNING LOGGER ON A logger is off and inactive when the screen is blank To turn on the logger press and hold the Power button for 2 seconds The display will Power on with the letters...

Page 4: ...list of loggers in range with status and temperature data HISTORY View a list of all LOG IC BT loggers that have been connected to your smart device CONFIGURATION SETTINGS Set default profile settings...

Page 5: ...TION DISPLAY ABBREVIATIONS bP Button Press AP Airplane Mode So Soak Mode rdY Ready LOG IC 360 BT Getting Started SINGLE MODE BATCH GROUP MODE SHOW LIST BATCH GROUP MODE HIDE LIST 2020 American Thermal...

Page 6: ...stomized for your usability Step 1 Select Step 2 Click on each option to adjust settings Vibrate on Connect Read Range Display Units Firmware Notifications Legacy Scanning Date Time Display Option Gra...

Page 7: ...notes in your configuration you will be prompted to type these notes or scan a QR code for details Step 7 The app will read DEPLOYED SUCCESSFULLY and the current temperature or SO for soak will be di...

Page 8: ...e this process for up to 4 alarms Within the Details section you can set Start Mode Soak Time Units of Measure Airplane Mode Log Interval High Speed Logging User Notes Circular Buffer Older data will...

Page 9: ...etails section you can set Start Mode Soak Time Units of Measure Airplane Mode Log Interval High Speed Logging User Notes Circular Buffer Older data will be overwritten with new data once max time is...

Page 10: ...details Step 6 The app will read DEPLOYED SUCCESSFULLY and the current temperature or SO for soak will be displayed on the logger screen The device will show as ACTIVE in the Scanner screen of the app...

Page 11: ...TO ANY DEVICE Step 1 Select Step 2 Select your Profile Step 3 Select Open Logger Scanner from the bottom navigation Step 4 Scan the QR code on the back of the logger you wish to activate with the sel...

Page 12: ...Step 1 Select Step 2 Select the profile of your choice Step 3 The device will begin scanning for BT devices within range that are not currently logging Step 4 Click Batch Group Mode and begin selectin...

Page 13: ...the necessary steps download the temperature data Step 4 The marked points will be displayed as blue targets within the device graph the PDF report the CSV file 2020 American Thermal Instruments Inc A...

Page 14: ...ms have been triggered Continuously click and release the Power button for more detailed temperature data Minimum temperature reached Maximum temperature reached Average temperature reached Battery li...

Page 15: ...g Data Download and History DOWNLOAD Start Date Location Mode Run Time Max Run Time Battery Level Soak Time Log Interval Sample Count Status Min Max Temp Alarm Settings Detailed Graph You can zoom in...

Page 16: ...in the top right of the App screen to share the temperature data via CSV or PDF Step 2 Using the native share function from your phone you can message or email the data Data Download and History DOWNL...

Page 17: ...Step 4 Select Download Deploy You will be prompted to either download and stop monitoring or download only Step 5 Data will begin downloading Download complete will appear when finished with a Zip fil...

Page 18: ...f loggers will now begin to download Step 6 Select the Zip file icon to send along to key stakeholders HISTORY The LOG IC 360 BT App stores temperature and humidity data for any logger that has been s...

Page 19: ...ce will connect and stop the logger Your logger will now read End on the LCD screen Step 5 Hold the Power button down for another 2 seconds and the display will turn off Your logger is now stopped and...

Page 20: ...duire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement The internal battery i...

Reviews: