6.  

Cautions 

 

1,   

Never remove any connecting parts when the tank is under 

 

 

pressure. 

2,   

Never remove any electrical parts before isolating the  

 

 

electrical supply. 

3,   

Never adjust the pressure switch unnecessarily  

4,   

Always ensure that the electrical supply is sufficient for the 

 

 

compressor. 

5,   

Never use the electrical plug to start or stop the compressor. 

6,   

If the pressure switch isn’t working, switch off the machine 

 

 

immediately to reduce any long term damage. 

7,   

Replacement lubricant must be new and clean and should be 

 

 

filled to the red cycle of the oil site glass.  

8,   

Be sure to drain the tank daily. 

9,   

Check oil level daily. 

 

 
 
7.  

Maintenance 

 

1,   

Clean crankcase and renew lubricant oil after the first 10  

 

 

working hours. 

2,   

Remove the drain valve to remove water from the tank daily 

3,   

Replace air filters every 120 hours of use or as and where 

 

 

they require replacement. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ZC224

Page 1: ...Air Compressor Operation Manual ZC224 ZC250 Before operation be familiar with the operation manual first...

Page 2: ...ge 1 3 Technical Specification Page 1 4 Preparation before Starting Page 2 5 Operation and Adjustment Page 2 6 Cautions Page 3 7 Maintenance Page 3 8 Trouble Shooting Page 4 9 Parts Diagram Page 5 Par...

Page 3: ...w and Main Components Fig 1 1 Pump 2 Pressure Switch 3 Outlet Valve 4 Regulating Valve 5 Pressure gauge 6 Non Return Valve 7 Drain Valve 8 Wheel 9 Delivery Pipe 10 Air Receiver 11 Safety Valve 12 Fan...

Page 4: ...below 10 deg 11 Set the pressure switch to the On position Fig 2 let the compressor run for 10 minutes with no load to ensure lubrication of the moving parts before regular operation 5 Operation and A...

Page 5: ...stop the compressor 6 If the pressure switch isn t working switch off the machine immediately to reduce any long term damage 7 Replacement lubricant must be new and clean and should be filled to the r...

Page 6: ...or abnormal noise 1 Connecting parts loose 2 Foreign object is the pump 3 Piston hitting valve seat 4 Moving parts worn 1 Check and retighten 2 Check and Clean 3 Replace with thicker gasket 4 Repair o...

Page 7: ...5 9 Parts Diagram...

Page 8: ...pe 1 11 Connecting Rod 1 38 Stator 1 12 Crankcase 1 39 Bearing 6203 1 13 Crank 1 40 Motor Cover 1 14 Hex Bolt M8 x 22 1 41 Bolt M5 x 105 4 15 Rubber Gasket 1 42 Fan 1 16 Breather Plug 1 43 Circlip 1 1...

Page 9: ...d cooling airflow All single phased compressors fitted with a 13amp plug are designed to plug directly in to a standard 13amp socket Exclusion to warranty cover are detailed below A The cost of routin...