background image

Operating instructions

3

1.  General Comment

The radar barrier is a contactless measuring method and can be used for metallic as well as non-metallic 
ducts, bunkers, shafts, free-falling stretches, expansion bellows etc. Since it can penetrate non-conductive 
material, e. g. such as plastics, it is possible to detect from the outside or through a window. The metering 
thus can be completely decoupled from the process, e. g. for measuring aggressive, abrasive or bulky 
material.

Even at difficult conditions - like temperatures of up to 1000 °C, pressure of up to 20 bar or all dust Ex- 
zones - the ProGap can be used by means of a process adapter.

2.  Mounting and Installation

The fitting position of the devices is arbitrary, however, absolute attention must be paid to the same fitting 
position of transmitter and receiver (marking of each device at the top) and to the very exact justification to 
each other (see below fig.).

Fig. 1: Installation

Transmitter and receiver must face each other with their front side on the same level.

Finally, it is important that the ProGap is mounted in a place where are no or only very weak vibrations.

Summary of Contents for ProGap

Page 1: ...SWR engineering Messtechnik GmbH ProGap Microwave barrier EN Operating Instructions ...

Page 2: ...nstructions 2 CONTENTS Page 1 General Comment 3 2 Mounting and Installation 3 3 Electrical Connection 4 4 Safety 5 5 Commissioning 6 6 Trouble Shooting 7 7 Notice 7 8 Declaration of Conformity 7 9 Technical Data 8 ...

Page 3: ...y material Even at difficult conditions like temperatures of up to 1000 C pressure of up to 20 bar or all dust Ex zones the ProGap can be used by means of a process adapter 2 Mounting and Installation The fitting position of the devices is arbitrary however absolute attention must be paid to the same fitting position of transmitter and receiver marking of each device at the top and to the very exa...

Page 4: ...transmitter and receiver mustn t be exactly parallel to each other in this installation because in that case the signal of the transmitter is not reflected to the receiver The installation should be slightly angled According to the rule arriving angle emergent angle a slightly angled positioning depending on the distance to the opposite wall is necessary The distance covered by the microwave in th...

Page 5: ...barrier 4 3 Operational Safety The microwave barrier must be installed by trained and authorised personnel only In case of maintenance work on the pipe or on components of the ProGap sensor make sure that the piping is in unpressurized condition Switch off the supply voltage for all maintenance cleaning or inspection works on the tubes Before sweat works the microwave barrier must be removed The c...

Page 6: ...se until the green LED goes out Repeat this procedure If the green LED still lights even with a complete left turn of P1 and furthermore the material has a low dielectric constant and weak damping e g paper plastics foams etc please contact SWR engineering GmbH If the red LED should not light put the switch S1 to position 2 with it the delicacy is doubled If the LED does not light even in this mos...

Page 7: ...r to receiver The distance between transmitter and receiver is too large 7 Notice Avoid reflections on metallic parts 8 Declaration of conformity The called product agrees with the regulations of the following European directives Number 89 336 EWG Text Electromagnetic Compatibility The correspondence of the called product with the regulations of the directive No 89 336 EWG is proved by the entire ...

Page 8: ...nge 0 4 m 0 18 m 18 m on demand Power supply 24 V DC 10 15 24 V AC 10 15 Power consumption approx 1 8 VA Current consumption max 100 mA Relay output max voltage current capacity 120 V AC DC 1 25 A 150 VA 50 W Response time 0 25 s 5 s continuously adjustable Measuring frequency K Band 24 125 GHz 100 MHz Transmitting power max 5 mW Weight Transmitter 1 1 kg Receiver 1 1 kg SWR engineering Messtechni...