Be sure faucet spout and body are in position, and align the slotted washer and
spacer to allow access to hose barbs. Tighten the hex nut while holding the
faucet in position with a padded crescent wrench. Do not over tighten.
C.4 Angle Stop Valve Installation
4.1 Turn off cold water supply.
4.2 Disconnect riser hose from cold water supply valve.
4.3 Ensure that sealing gasket is fully seated into angle stop valve female thread.
Install angle stop valve (female thread side) on cold water supply valve.
4.4 Connect riser hose to angle stop valve on male thread side.
DO NOT open the angle stop valve or cold water supply valve at this time.
C.5 Drain Saddle Assembly Installation
The RO system comes supplied with a drain saddle and mounting hardware
which fits around a standard 1½” O.D. drain pipe.
5.1 The drain saddle should be installed above the trap, on the vertical or
horizontal tailpiece. It should never be placed close to the outlet of a
garbage disposal.
5.2 Drill a 5/16” hole in the drain pipe in the location where the drain saddle
will be positioned. Support the drain against drilling pressure. Do not drill
through both sides of the drain pipe. If possible, place the hole so the drain
saddle fitting will angle toward the faucet location.
5.3 Position the drain saddle so that the drain fitting is over the hole in the drain
pipe.
5.4 Tighten the drain saddle screws evenly and firmly so a good seal is made.
Avoid over tightening.
Note: Some state or local codes may require that the drain saddle be served
by a trap other than the one serving the garbage disposal. Before making a
connection, please check your code regulations.
C.6 Pressurized Storage Tank Valve Installation
6.1 Remove the protective plastic cap from the 1/4” NPT fitting on the top of
the storage tank.
6.2 Wrap the 1/4” NPT fitting with Teflon tape (plumbers tape).
6.3 Thread the storage tank valve onto the 1/4” NPT fitting.Avoid over tightening.
C.7 Filter Cartridge Installation
7.1 Unscrew the filter housing sumps by hand or with a spanner wrench.
7.2 Rinse out each of the housings and fill about 1/3 full with water. Add about
2 to 3 tablespoons of bleach and scrub thoroughly with a brush or sponge.
Rinse thoroughly.
7.3 Install the cartridge into the sump making sure that it slips down over the
sump standpipe.
7.4 Turn the sump into the cap and hand tighten. Do not over tighten.
5