2 0 6 3 6 5 R e v. 8 0 9 U F S . 1 0 . 8 0 9 . 7. U
1 0 . 1 0
|
R E P L A C I N G T H E T H E R M A L F U S E
Required Tools:
Small flat screwdriver, 10 mm wrench.
Removal
•
Remove the two (2) protective cover nuts.
•
Loosen the two (2) cable grip nuts and pull cover away
along cables.
•
Remove cable #4 wires from the white terminal strip.
•
Remove nut securing white terminal strip to the
steam generator.
•
Remove thermal fuse.
Installation
•
Push thermal fuse all the way into position.
•
Secure white terminal strip to steam generator.
•
Connect cable #4 wires to the white terminal strip.
•
Install protective cover nuts and tighten cable grip nuts.
1 0 . 1 1
|
R E P L A C I N G T H E W A T E R
L E V E L S E N S O R
Required Tools:
Large pliers and heat resistant silicone.
Removal
•
Disconnect cable #17 wires from the level sensor.
•
Unscrew water level sensor from the steam generator reservoir.
Installation
•
Coat threads with heat resistant silicone and install into the
steam generator reservoir.
•
Connect cable #17 wires to the level sensor.
NOTE:
Be sure that small triangle is directed down.
NOTE:
If you change water level sensor, check that the thermal fuse
and heating element are in proper working order.
Name
Part Number
Water level sensor
302240-08
Thermal Fuse
302240-07
Heating Element
302240-38
S p a F e n g S h u i - P a g e 3 3
Owner’s Manual
SECTION 10 |
Service