m) Security function for invalid access attempts
The code lock may be locked if ten invalid access attempts have been made consecutively
(for example, in an attempt to test transponders).
The following functions are available:
•
No lock (default setting)
Invalid access attempts are ignored.
•
Lock for ten minutes
If ten invalid access attempts have been made via the transponders or fingerprints, the
code lock will be locked for ten minutes. The control LED will flash red. During this time,
access cannot be gained, even with valid transponders or fingerprints.
•
Triggering an alarm
If ten invalid access attempts have been made with transponders or fingerprints, the code
lock will emit an alarm sound, and the alarm output will be activated (thus an alarm siren
can be operated; otherwise, the alarm output can be connected to an alarm system).
The alarm duration is adjustable (1...3 minutes is possible, one minute by default), as
described in chapter 10. l). The alarm can be cancelled using a valid transponder or
fingerprint.
Proceed as follows:
•
The code lock must be in standby mode; the control LED lights up red.
• Activate programming mode, as described in chapter 10. b); then the control LED will flash
red. Example:
•
Press the button. The control LED will light up orange.
•
Enter the desired function:
= Security function disabled
= Lock for ten minutes
= Trigger an alarm
•
Press the
button to confirm your entry. The control LED briefly lights up green and then
flashes red (programming mode).
•
To exit programming mode, press the button. The control LED now glows red steadily,
and the code lock is in standby mode.
48