19
e) Deleting all user transponders
• Enable the programming mode as described in section 8. a); the LED starts to flash red.
•
Enter the programming code to delete the transponders. The yellow LED will then light up.
•
Enter the master code again.
•
Press the
button to exit the delete mode. The LED flashes red again, which means that you can continue pro
-
gramming or exit the programming mode with the button.
Example for deleting all transponders (programming mode must be active, see section 8. a); the default master code
“123456” is used as an example; you must use your own master code:
f) Setting the changeover contact activation time
This function enables to set the changeover contact activation time from 1 to 99 seconds after a valid access to the
code lock (default setting is 5 seconds).
When “0” is set, the changeover contact goes to “toggle” mode. Each valid access to the code lock changes the
changeover contact switch position. This can be used to enable/disable an alarm system.
Proceed as follows:
• Enable the programming mode as described in section 8. a); the LED starts to flash red.
•
Enter the programming code to set the activation time. The yellow LED will then light up.
•
Enter the desired changeover contact activation time. You can set from ..... (1 - 99 seconds).
Example 1: Activation time is 8 seconds:
Example 2: Toggle mode:
•
Press the
button to exit the setting mode. The LED flashes red again, which means that you can continue pro
-
gramming or exit the programming mode with the button.
Example 1 for a 4-second activation time (programming mode must be active, see section 8. a):
Example 2 for toggle mode (programming mode must be active, see section 8. a):