15. Technical data
a) Access system
Power supply ........................................12 - 18 V/DC
Power consumption ..............................Standby <50 mA
Frequency band ....................................124.6 - 125.4 kHz
Transmission power..............................11.62 dBm
Max. reading distance ..........................approx. 3 cm
Data retention in case of a power cut ...yes
Suitable transponders ...........................Commercially available EM transponders for frequency 125 kHz
Output ...................................................Potential-free single-pole changeover contact (relay)
Max. contact rating 24 V/DC, 2 A
Adjustable switching time (1 - 99 seconds or toggle mode; default setting: 5
seconds)
Wiegand connection .............................yes (output = 26-bit protocol, input = 26/34-bit protocol with automatic
recognition)
Transponder memory cells ...................2000
Mounting location .................................indoors/outdoors
Protection class ....................................IP66
Ambient conditions ...............................Temperature -40 °C to +60 °C
Cable length .........................................approx. 25 cm
Dimensions ...........................................115 x 70 x 25 mm (H x W x D)
Weight ..................................................approx. 185 g
b) IR remote control
Operating voltage .................................3 V/DC via 1x CR2025 battery (lithium coin cell)
Max. IR range .......................................approx. 1 m