26
7.8 Electrical installation
The means for disconnection from the power supply must be incorporated in the fixed wiring in accordance with
the wiring rules.
WARNING! Safety hazard!
The product should only be installed by people with relevant electrical knowledge and experience! *)
If it is not installed properly, you risk:
your own life
the life of user of the electrical device
severe damage to property, e.g., by fire
personal liability for personal injury and material damage
Always consult an electrician!
*) Technical knowledge required to perform the installation:
For the installation, the following specialist knowledge is required in particular:
The “Five safety rules”: Disconnect from the mains; protect against accidental switch-on; ensure there is no volt-
age; earth and short-circuit; cover or protect adjacent live parts
Use of suitable tools, measuring devices and personal protective equipment, where necessary
Analysis of measurement results
Use of electrical installation materials to meet the requirements for disconnection
IP protection ratings
Installation of electrical installation materials
Type of power supply (TN system, IT system, TT system) and the corresponding connection criteria (classic earth-
ing, protective earthing, necessary additional measures etc.)
If you are not a professional, do not do it yourself, have it performed by a specialist.
7.9 Installation
The attachment to the ceiling should have sufficient strength to support 4x the weight of the ceiling fan.
When penetrating the surface e.g. drilling or inserting fasteners, make sure no cables or pipes are damaged.
Mounting of the suspension system should be performed by the manufacturer, its service agent, or suitably quali-
fied persons.
The fan should be installed so that the blades are more than 2.3 m above the floor.