background image

This manual, Code 20123380 - Rev. 0 (03/17) comprises 12 pages.

2

GENERAL INFORMATION

RANGE

MODEL

CODE

SOL R - 7,5m

20116164

Dear heating engineer,

We would like to congratulate you on having recommended 

S

 solar station unit: a modern product that's capable 

of ensuring a high degree of reliability, efficiency, quality 

and safety.

While your technical skills and knowledge will certainly be 

more than sufficient, this booklet contains all the informa-

tion that we have deemed necessary for the device's cor-

rect and easy installation.

Thank you again, and keep up the good work,

Sylber

              

CONTENTS

ENGLISH

1  GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and 

as ordered as soon as you receive it. Report any dis-

crepancies or damage to the 

S

 dealer who sold it.

This product must be installed by a legally qualified 

heating engineer. On completion of the installation, 

the installer must issue the owner with a declaration 

of conformity confirming that the installation has been 

completed to the highest standards in compliance 

with the instructions provided by 

S

 in this instruc-

tion manual, and that it conforms to all applicable 

laws and standards.

This product must only be used for the purpose 

for which it is designed and made, as specified by 

S

S

 declines all responsibility, contractual or 

other, for damage to property or injury to persons or 

animals caused by improper installation, adjustment, 

maintenance or use.

The product must be serviced at least once a year. 

Servicing must be arranged in advance with the 

S

 Technical Assistance Centre.

All servicing and repairs must be performed by a 

qualified heating engineer.

This instruction manual is an integral part of the prod-

uct. It must be kept safe and must ALWAYS accom-

pany the product, even if it is sold to another owner or 

transferred to another user or to another installation. 

If you lose this manual, order a replacement immedi-

ately. Keep the product purchase documents to be 

presented to the 

S

 authorised Technical Assis-

tance Centre to request a service call under warranty.

Size the solar expansion tank so as to ensure com-

plete absorption of the expansion of the fluid con-

tained within the system, with reference to the prevail-

ing regulations on the matter. In particular, consider 

fluid characteristics, considerable fluctuation of ser-

vice temperature and vapour that might be generated 

during solar collector stagnation stage. Proper size 

of expansion tank ensures setting off of all volume 

changes of the heat transfer fluid, avoiding excessive 

pressure increase. Limited pressure changes avoid 

reaching safety valve opening pressure and the con-

sequent fluid drainage.

General information

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution 

and adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

This manual, Code

- Rev.

comprises

pages.

GENERAL INFORMATION                                      2

General Safety Information  . . . . . . . . . . . . . . . . .  2

2 Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

Description of the appliance  . . . . . . . . . . . . . . . .  3

Safety and control devices. . . . . . . . . . . . . . . . . .  3

5 Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3

System layout. . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

Technical specifications. . . . . . . . . . . . . . . . . . . .  4

INSTALLATION                                                        5

Unpacking the product  . . . . . . . . . . . . . . . . . . . .  5

Installation premises  . . . . . . . . . . . . . . . . . . . . . .  5

10 Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

11 

Water connections . . . . . . . . . . . . . . . . . . . . . . . .  6

12 

Pump controller  . . . . . . . . . . . . . . . . . . . . . . . . . .  6

13 

Electrical connections  . . . . . . . . . . . . . . . . . . . . .  8

COMMISSIONING AND MAINTENANCE               9

14 

System flushing  . . . . . . . . . . . . . . . . . . . . . . . . . .  9

15 

System filling cock . . . . . . . . . . . . . . . . . . . . . . .  10

16 

Device cleaning and maintenance  . . . . . . . . . .  11

17 

Interventions on the hydraulic system  . . . . . . . .  11

18 

Recycling and disposal  . . . . . . . . . . . . . . . . . . .  11

Summary of Contents for SOL R-7,5M

Page 1: ...SOLAR STATION SOL R 7 5M INSTALLATION AND MAINTENANCE MANUAL ...

Page 2: ... qualified heating engineer b This instruction manual is an integral part of the prod uct It must be kept safe and must ALWAYS accom pany the product even if it is sold to another owner or transferred to another user or to another installation If you lose this manual order a replacement immedi ately Keep the product purchase documents to be presented to the S authorised Technical Assis tance Centr...

Page 3: ...pervised a Do not dispose of packaging material into the envi ronment or leave it within the reach of children since it can become a potential hazard Dispose of packag ing material in compliance with applicable legislation 3 DESCRIPTION OF THE APPLIANCE The solar station SOL R allows transferring sun power from collectors to a storage system The solar station S is enclosed in a PPE Polypropylene f...

Page 4: ...fitting 7 TECHNICAL SPECIFICATIONS DESCRIPTION return solar station Maximum working pressure 6 bar Maximum operating temper ature 110 C Dimensions LxHxP 264x362x215 mm Net weight with insulation 3 8 kg Power supply 230 50 V Hz Min max electrical current draw 0 04 0 48 A Min Max power consumption 2 45 W Useful head available Return solar station USEFUL HEAD AVAILABLE mbar 800 700 600 0 500 400 300 ...

Page 5: ... to permit easy maintenance 9 1 Recommended minimum distances Recommended distances for assembly and maintenance are 300 mm on each side including expansion tank Put the solar station at a proper hight to allow thermometer and pressure gauge reading 0 3 m 0 3 m 0 3 m Installation 10 ASSEMBLY Remove the front insulation 1 Mark mounting points F on the wall and drill Insert blocks not supplied F F 7...

Page 6: ...ls can be used seal fittings with high temperature sealant 180 C suitable for solar applications 12 PUMP CONTROLLER The circulator is produced with maximum idraulic head configuration of 7 5 meter USER INTERFACE The user interface consists of a push button 1 a red green LED 2 and four yellow LEDs 3 1 2 3 LED 1 LED 2 LED 3 LED 4 LED 5 When necessary the user interface provides access to Functioning...

Page 7: ...or an external control if green it indicates the circulator performance or internal control possibility Led n 2 and 3 indicate different control mode possibility and led n 4 and 5 indicate the curve type setting 1 2 3 o 4 These leds are yellow PWM mode LED 1 LED 2 LED 3 LED 4 LED 5 Curve 1 4 5m Red Yel low Curve 2 5 5m Red Yel low Yel low Curve 3 6 5m Red Yel low Yel low Yel low Curve 4 7 5m Red Y...

Page 8: ...own in the figure PWM CONNECTOR POWER SUPPLY To control the circulator in on off mode the PWM cable is not required To control the circulator in modulating mode by using a solar regulator verify the compatibility between the chosen regu lator and the PWM signal see following paragraph CON TROL SIGNALS CONTROL SIGNALS The circulator can be controlled with a low voltage PWM digital signal pulse widt...

Page 9: ...UiL 1 V Input signal current IiH 10 mA Input Duty cycle PWM 0 100 14 SYSTEM FLUSHING Before filling the system with mixture of water and glycol it is necessary to flush the pipes of the solar system to elimi nate all residues of fluid or scale Proceed as follows Verify the flow meter C is completely open Turn handle on valve VR clockwise Open taps A and B on the return tube Flush water in through ...

Page 10: ...ol and water PC PC Heat transfer fluid filling pump To fill the system proceed as follows Verify the flow meter C is completely open Connect the filling pump PC as shown Turn handle on valve VR clockwise Open taps A and B on the return tube Open manual degassing tap and any bleeder valve located at the highest points of the system and keep them open throughout the filling procedure Pump the heat t...

Page 11: ...afety data sheet supplied with the glycol 17 2 Disassembling the circulator b Remove the circulator when system has cooled down Before removing circulator C Cut power off to the solar station and to the connect ed integration system by setting the system s main switch and the device s main switch to OFF Disconnect circulator power by removing connectors D and E Move away any wiring and electric de...

Page 12: ...ento 23 A 23900 Lecco LC www sylber it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Reviews: