17. Electrical System
17-22
Thermo Unit
Remove the thermo unit.
Hang the thermo unit in an oil heater, heat the oil
and measure the resistance at each temperature.
Temperature
50‚C
80‚C
100‚C
120‚C
Standard (
Ω
) 134~149 47.5~57.0 26~29 14.8~17.2
Caution
Wear gloves and goggles when performing this
test.
Caution
Engine oil should be used as a heating medium
as the test temperature must be higher than
100
℃
.
Contacting the container wall by the
thermometer and the thermo unit may result in
wrong readings.
Water Temperature Meter
Disconnect the thermo unit coupler and connect it
to engine ground.
Turn on the main switch.
The needle of the water temperature meter should
move to other end, H position.
Caution
Do not ground the water temperature more
than 5 seconds, or the meter will be damaged.
Thermo sensor
Thermo unit
To this chapter contents
Summary of Contents for Citycom.300i
Page 5: ...Serial Number Home page Contents...
Page 38: ...2 Maintenance Information 2 17 Note To this chapter contents...
Page 46: ...3 LUBRICATION SYSTEM 3 8 Notes To this chapter contents...
Page 106: ...4 Fuel Injection System 4 60 Note To this chapter contents...
Page 173: ...10 AC Generator Starting Clutch 10 10 Notes To this chapter contents...
Page 195: ...12 Cooling System 12 14 Notes To this chapter contents...
Page 223: ...14 Brake System 14 12 Note To this chapter contents...
Page 244: ...17 Electrical System 17 5 FUSE Fuse circuit diagram To this chapter contents...
Page 262: ...17 Electrical System 17 23 Note To this chapter contents...
Page 270: ...19 Electrical Diagram 19 1 Home page Contents LH30W EFi Electrical Diagram 19...