14
10. INSPECTION AND MAINTENANCE BEFORE RIDING
OIL CHANGE:
y
Change engine oil after the first 300km, and change the engine oil
every 1000km thereafter.
y
In order to maintain the engine’s maximum performance, check
whether the engine oil is enough every 500km. Add oil to upper
limit if the engine oil has been found to be inadequate.
y
Engine Oil : Use (API) SL/CFSAE 10W-30 grade or better engine
oil. Otherwise, damage will not be covered by warranty.
y
Use SAE 5W-40 engine oil when outside temperature is below 0
℃
※
Recommended Oil:
SYM Genuine 4X OIL.
y
Oil
Capacity
:
TONIK 125CC
: 0.75 Liter (0.60 liter for routine change).
TONIK 50CC
: 0.80 Liter (0.65 liter for routine change).
oil filter change: 0.60
~
0.65 liters.
【
Oil Filter Cleaning
】
The oil filter nut assembly of the element, and remove the
element. Remove the foreign materials from the element by
using a gasoline or air spraying gun.
WARNING:
y
Oil level will not be correct when checking the oil level with
the motorcycle parked on an unleveled ground or
immediately after the engine stopped.
y
Engine and exhaust pipe are hot right after engine stopped.
Pay special attention not to get burned when checking or
replacing engine oil.
y
If the oil lever approach lower limit again after refilled, check
the engine for leaks and refill it again.
y
Keep away from spark and flames when refilling the oil.
§
FUEL INSPECTION
§
y
Turn main switch key to “ON” position, and check fuel gauge’s needle range to make sure there is
enough amount of fuel in the fuel tank.
y
This motorcycle’s engine is designed for using the unleaded fuel of Octane 90 or above.
y
Firmly secure the main stand on the ground, shut off the engine and keep flames away from the
motorcycle when refueling.
y
Do not fill above fuel upper limit lever when refueling.
y
Make sure the fuel tank cap had been tighten properly.
§
TRANSMISSION OIL INSPECTION AND CHANGE
§
INSPECTION:
y
Use the main stand to support the motorcycle on a level ground, after the engine stops, wait for 3~5
minutes. Remove the transmission oil infusion bolt, put a measuring glass under the drain bolt, and
remove the drain bolt. Let the oil flows into measuring glass and check for decreased or not. (at
disassembly:110c.c/at change:100c.c.).
OIL REPLACEMENT:
y
Stop the engine and use the main stand to support your motorcycle on a lever ground. Remove the
infusion bolt and drain bolt, drain out the oil.
y
Install the drain bolt and tighten it. Fill new transmission oil (90~100c.c.), and install the infusion bolt
and tighten it. (make sure that bolts are tightened and check that there’s no leakage.)
y
Recommend Oil: Genuine SYM HYPOLD GEAR OIL (SAE 85W-140).
Upper limit
Oil filter
Filter nut
Lower limit