4-23
LS 1000 Product Reference Guide: Chapter 4, Programming the LS 1004
I 2 of 5 Modulo 10 Check
When enabled, this parameter checks the integrity of a Interleaved 2 of 5 symbol to
ensure it complies with specific algorithms.
ITF14/EAN13 Conversion
This feature converts a 14-character I 2 of 5 code into EAN13, and transmits to the host
as EAN13. In order to accomplish this, the I 2 of 5 code must be enabled, one length
(either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero
and proper trailing check digit.
I 2of 5 Modulo 10
Check Digit Enable
I 2of 5 Modulo 10
Check Digit Disable
ITF-14/EAN-13 Conver-
sion
ITF-14/EAN-13 Conversion
Disable
coverBook Page 23 Monday, December 1, 1997 2:19 PM