Ergonomic Recommendations

Caution:

 In order to avoid or minimize the potential risk of ergonomic injury follow the 

recommendations below. Consult with your local Health & Safety Manager to ensure 
that you are adhering to your company’s safety programs to prevent employee injury.

• Reduce or eliminate repetitive motion
• Maintain a natural position
• Reduce or eliminate excessive force
• Keep objects that are used frequently within easy reach
• Perform tasks at correct heights
• Reduce or eliminate vibration
• Reduce or eliminate direct pressure
• Provide adjustable workstations
• Provide adequate clearance
• Provide a suitable working environment
• Improve work procedures.

SPT 1800 does not 
accept scan input.

Scan application 
not present.

Verify that the SPT 1800 is loaded with 
a scanning application. See your Sys-
tem Administrator.

Bad bar code.

Check to be sure the bar code symbol 
is not defaced.

Too far away 
from bar code.

Be sure you are within proper scanning 
range.

Bar code type is 
not enabled.

Be sure the SPT 1800 is programmed 
to accept the type of bar code you are 
scanning.

Beep is not en-
abled.

If you are expecting a beep on a good 
decode and don’t hear one, check that 
the application is set to generate a 
beep on good decode.

Battery is low.

If the scanner stops emitting a laser 
beam when you press the trigger, 
check your battery level. When the bat-
tery is low, the scanner shuts off before 
the terminal notifies you of the low bat-
tery condition.
Note: If, after performing these checks, 
the scanner is still not reading sym-
bols, contact your distributor or Symbol 
Technologies.

Problem

Cause

Solution

Summary of Contents for SPT 1800 Series

Page 1: ...S P T 1 8 0 0 S e r i e s S P T 1 8 0 0 S e r i e s...

Page 2: ...6 787 5 278 398 5 280 162 5 280 163 5 280 164 5 280 498 5 304 786 5 304 788 5 306 900 5 321 246 5 324 924 5 337 361 5 367 151 5 373 148 5 378 882 5 396 053 5 396 055 5 399 846 5 408 081 5 410 139 5 41...

Page 3: ...procedures for the setup and use of the terminal Specific topics covered include Parts of the SPT 1800 on page 2 Installing the SIM Card SPT 1834 Only on page 5 Installing the Battery on page 6 Start...

Page 4: ...of the SPT 1800 Menu Icon Front View Application Buttons Scroll Button Up and Down Center Scan Button Right Scan Trigger LCD Screen Find Icon Contrast Button Laser Decode LED Scroll Button Up and Down...

Page 5: ...3 Q u i c k R e f e r e n c e Parts of the SPT 1800 continued Bottom View Top View Serial Port Scanner Exit Window Left Scan Trigger Left View...

Page 6: ...inued Speaker Handstrap Connector Handstrap Connector WAN Antenna Back View Stylus Stylus Silo Handstrap Connectors Battery Latches Lithium Ion Battery Reset Button Infrared Port SIM Socket Battery Co...

Page 7: ...PT 1834 Only Open the latches on the battery cover and lift it away from the SPT1834 Metal Clip SIM Card Contact Area 1 Slide the metal clip to the left to release the SIM cardholder 2 Lift the cardho...

Page 8: ...0 mAh Lithium ion battery p n 21 52319 01 All other SPT 1800 Series terminals use Lithium ion battery p n 20 36098 01 Before using your SPT 1800 for the first time charge the battery using the cradle...

Page 9: ...attery fully charges in approximately 2 5 hours See the CRD 1800 Cradle Quick Reference Guide for more information Note When the battery is fully charged the cradle s charging LED lights green The CRD...

Page 10: ...does not power on perform a hard reset See Performing a Hard Reset on page 12 Calibrating the Screen The first time you start your SPT 1800 the Welcome utility appears Follow the steps to align the i...

Page 11: ...enter of each target that appears on the screen with the tip of the stylus If at any time you need to recalibrate the screen open the Preferences application tap General on the top right corner of the...

Page 12: ...contrast control button or tap Done on the screen to turn off the contrast control Writing with the Stylus Your SPT 1800 includes Graffiti handwriting software for entering text and numbers Graffiti...

Page 13: ...ack into the audio connector on the top of the terminal Applications Icon Exits the current application and lists available applications for selection Calculator Icon Displays the calculator applicati...

Page 14: ...o restarts your terminal but erases all records and entries stored in your SPT 1800 Therefore never perform a hard reset unless a soft reset does not solve your problem Note You can restore any data p...

Page 15: ...lding it for extended periods of time To attach the handstrap for the SPT 1834 1 Put the side slots of the thread ed button over the wire clips on the handstrap 2 Screw the button into the threaded sl...

Page 16: ...re the red scan beam covers the entire bar code The green scan LED lights and a beep sounds to indicate a successful decode Scanning PDF417 2 D Bar Codes To scan a PDF417 bar code with a 2 D configure...

Page 17: ...sure the scan line extends at least 1 2 past the left and right edges of the bar code Hold the scanner closer for denser symbols farther away for larger symbols Make sure you scan the top and bottom r...

Page 18: ...t do not expose it to rain or moisture for an extended period Treat your SPT 1800 as you would a pocket calculator or other small electronic instrument The touch sensitive screen of your SPT 1800 cont...

Page 19: ...normal It takes a minute for the battery gauge to accurately show the condition of the battery No sound Sound setting is set to off in the Preferences sec tion Check the Sound options in the Gener al...

Page 20: ...n modes Tapping the screen buttons or icons does not activate the corresponding fea ture Screen is out of calibration Recalibrate the digitizer Choose Digi tizer from the Preferences application pick...

Page 21: ...t scan input Scan application not present Verify that the SPT 1800 is loaded with a scanning application See your Sys tem Administrator Bad bar code Check to be sure the bar code symbol is not defaced...

Page 22: ...The laser classification is marked on one of the labels on the device Class 1 Laser devices are not considered to be hazardous when used for their intended purpose The following statement is required...

Page 23: ...SE 1 CLASE 1 PRODUCTO LASER DE LA CLASE 1 CLASSE 2 LUMIERE LASER CLASE 2 LUZ LASER NE PAS REGARDER LE RAYON FIXEMENT NO MIRE FIJAMENTE EL HAZ PRODUIT LASER DE CLASSE 2 PRODUCTO LASER DE LA CLASE 2 GER...

Page 24: ...gencies Use the hands free facility to speak only if it does not divert your attention from the traffic Safety on Aircraft You are required to switch off mobile phones when on board an aircraft or at...

Page 25: ...lly Hazardous Atmospheres You are advised not to use this device at a refuelling point You are reminded of the need to observe restrictions on the use of radio devices in fuel depots chemical plants e...

Page 26: ...uipment is restricted to 2 4465 2 4835 GHz frequency range Italy requires a user license for outside usage Statement of Compliance Symbol Technologies Inc hereby declares that this device is in compli...

Page 27: ...freight and insurance prepaid in North America Shipments from the US or other locations will be made F O B Symbol s manufacturing plant Symbol will use new or refurbished parts at its discretion and...

Page 28: ...ct manuals United States1 1 800 653 5350 1 631 738 2400 Canada 905 629 7226 United Kingdom 0800 328 2424 Asia Pacific 337 6588 Australia 1 800 672 906 Austria sterreich 1 505 5794 Denmark Danmark 7020...

Reviews: