Menu ARC Anatomy

Nearly all of the configuration and connection options are on the rear of the Menu ARCs except for the baud rate selection 
jumper (see Baud Rate Select section). The anatomy of a Menu ARC is outlined below:

ARC Audio Grounding Legend

J5 and J6: RJ45 “ARC” ports

The ARC ports distribute RS485 
data, power and an ARC Audio line 
to one or more ARC devices over 
standard CAT5 cable. These ports 
may be used to chain multiple ARCs 
or to home run back to any Symetrix 
rack mount device with an ARC 
port.

J9: ARC Audio Grounding

Two sets of jumpers at J9 configure 
the grounding of the ARC Audio 
pair. Refer to the legend below 
for positions. Refer to the 

ARC 

Network Design

 section for more 

information.

J7: RS485 Termination

Refer to the RS485 Termination 
section for more information.

S4: Device Address DIP Switches

Configures the device’s RS485 
bus address. Refer to the Device 
Addressing section for more 
information.

J8: RS485, Power and ARC Audio

When powering a Menu ARC from the 
included PS-6 power supply, RS485 
data and Power both connect here. 
Connect the PS-6 positive lead to 
“V+” and the negative lead to “GND”. 
The RS-485 shield or ground also 
connects to “GND” and the RS-485 
conductor pair connects the bus 
in a parallel fashion to “A” and B”. 
WARNING! Do not use at the same 
time as J5 or J6.
Additionally, ARC Audio connections, 
AF+ and AF-, are provided. Again, 
GND is shared.

Menu ARC Anatomy

Summary of Contents for ARC-2

Page 1: ...ARC 2 and ARC 2i Menu ARCs Quick Start Guide ...

Page 2: ...2 Quick Start Guide 6408 216th Street SW Mountlake Terrace WA 98043 USA T 1 425 778 7728 F 1 425 778 7727 www symetrix co Safety ...

Page 3: ...aratus shall be connected to a mains socket outlet with a protective earthing connection Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outl...

Page 4: ...ly for use with the ARC series of remotes DO NOT plug the ARC connectors on Symetrix products into any RJ 45 connector labeled SYMLINK ETHERNET or COBRANET The ARC RJ 45 connectors on Symetrix products can carry anywhere from 6 to 24 VDC which can damage SymLink Ethernet and CobraNet circuitry ARC ARC SYMLINK TRANSMIT RECEIVE COBRANET ETHERNET ETHERNET Warning ...

Page 5: ...item labeling parameter limits and firmware version upgrades are handled by software included with Symetrix DSP hardware Power control and a single channel of ARC Audio are connected via RJ 45 inputs or screw type barrier strips Intuitive Navigation Pressing the menu button navigates through the menu names The menu button also acts as a preset trigger when a preset list is scrolled The up down arr...

Page 6: ...Two sets of jumpers at J9 configure the grounding of the ARC Audio pair Refer to the legend below for positions Refer to the ARC Network Design section for more information J7 RS485 Termination Refer to the RS485 Termination section for more information S4 Device Address DIP Switches Configures the device s RS485 bus address Refer to the Device Addressing section for more information J8 RS485 Powe...

Page 7: ...sume 28 gauge CAT5 cabling maximum stated distances assume 24 gauge CAT5 cabling If power is not distributed over CAT5 each RS 485 chain will be limited to 1000 ft in a star network configuration and 4000 ft in a daisy chain network configuration Longer distances may be possible using third party RS 485 extender products Disclaimer From time to time we test the compatibility of our own products wi...

Page 8: ...or expander in to clean up the signal This technique does not provide much flexibility within the system design and therefore is not recommended Frequency response Frequency response can roll off due to the capacitance of a long cable run The amount of roll off is highly dependent on source impedance the output impedance of what is supplying the signal Most pro audio devices have low output impeda...

Page 9: ...mNet Designer s Help for information on setting the RS 485 baud rate Note the Menu ARC s faceplate will need to be removed in order to access this jumper J10 is just below the menu display Menu ARC DIP Switch Settings NOTE For the sake of space a small variety of configurations are shown A total of 31 devices per RS 485 bus are possible ADDRESS 1 ADDRESS 2 ADDRESS 3 ADDRESS 4 ADDRESS 5 ADDRESS 7 A...

Page 10: ...tration of a typical SymNet Network Audio Solution shows the place of the ARC PS in a large multi purpose network audio solution Restaurant Bar Banquet Meeting Rooms Lobby Wall Panel controls local volume source selection and time of day presets Wall Panels control local room BGM sources BGM and Mic volumes Wall Panels link when rooms are combined Wall Panel selects paging zones Restaurant Applica...

Page 11: ...uter Said software is specifically excluded from this warranty Limitation of Liability The total liability of Symetrix on any claim whether in contract tort including negligence or otherwise arising out of connected with or resulting from the manufacture sale delivery resale repair replacement or use of any product will not exceed the price allocatable to the product or any part thereof which give...

Page 12: ...esponsibility with regard to the performance or use of these products Under copyright laws no part of this brochure may be reproduced or transmitted in any form or by any means electronic or mechanical without permission in writing from Symetrix Inc If however your only means of access is electronic permission to print one copy is hereby granted The following are either Trademarks or Registered Tr...

Reviews: