QUICK START GUIDE:

 Solus NX 4x4, 8x8, and 16x8

Declaration of Conformity

We, 

Symetrix Incorporated

, 6408 216th St. SW, 

Mountlake Terrace, Washington, USA, declare under our 

sole responsibility that the products:

Solus NX 4x4, 8x8, and 16x8

to which this declaration relates, is in conformity with the 

following standards:

IEC 60065 (safety),

EN 55032, EN 55103-2, EN 61000-3-2,

EN 61000-3-3 (EMC-International),

FCC Part 15 (EMC-USA),

RoHS (health/environmental)

The technical construction file is maintained at:

Symetrix, Inc.

6408 216th St. SW

Mountlake Terrace, WA, 98043  USA

The authorized representative located within the European 

Community is:

World Marketing Associates

P.O. Box 100

St. Austell, Cornwall, PL26 6YU, U.K.

Date of issue: July 29, 2016

Place of issue: Mountlake Terrace, Washington, USA

Authorized signature:

Julia Ogden, COO, Symetrix Incorporated.

Configuring IP Parameters

Locating Hardware

Discovery of, and connection to, Solus NX 
4x4, 8x8, and 16x8 hardware is done with 
the Locate Hardware dialog found under the 
Hardware menu or by clicking the Locate 
Hardware icon in the tool bar or on a particular 
Solus NX 4x4, 8x8, and 16x8 unit itself.

IP Configuration with Composer

The Locate Hardware dialog will scan the 

network and list available units. Select the Solus NX 4x4, 8x8, 
or 16x8 unit you wish to assign an IP address to and click 
the Properties button. If you wish to assign Solus NX 4x4, 
8x8, or 16x8 a static IP address, select “Use the following 
IP address” and enter the appropriate IP Address, Subnet 
mask and Gateway. Click OK when finished. Now, back in 
the locate hardware dialog, ensure the Solus NX 4x4, 8x8, 
or 16x8 device is selected and click “Select Hardware Unit” 
to use this Solus NX 4x4, 8x8, or 16x8 hardware in your Site 
File. Close the Locate Hardware dialog.

The RJ45 connectors labeled “ARC” are only for use 

with the ARC series of remotes.  DO NOT plug the ARC 

connectors on Symetrix products into any other RJ45 

connector. The “ARC” RJ45 connectors on Symetrix 

products can carry up to 24 VDC / 0.75 A (class 2 wiring) 

which can damage Ethernet circuitry.

ARC Pinout

The RJ45 jack distributes power and RS-485 data to one 
or more ARC devices. Uses standard straight-through UTP 
CAT5/6 cabling.

!

    Warning! Refer to the RJ45 Warning for compatibility  

     information.
The Symetrix ARC-PSe provides serial control and power 

distribution over standard CAT5/6 cable for systems with 

more than 4 ARCs, or, when any number of ARCs are 

located long distances from a Symetrix DSP unit.

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1 • AUDIO (+) 
2 • AUDIO (-)
3 • COMMON GROUND
4 • RS-485 DATA (A)
5 • RS-485 DATA (B)
6 • COMMON GROUND
7 • POWER (+V)
8 • POWER (+V)

Note:

 

The ARC Audio line may be grounded at the

Symetrix rack-mount device and the ARC wall panel
to provide additional distance.

ARC PORT PINOUT

8

7

6

5

4

3

2

1

Pair 1

Pair 3

Pair 4

Pair 2

- or -

- or -

Summary of Contents for Solus NX 8x8

Page 1: ...e proper ESD control and grounding when handling exposed I O terminals BM Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus BN Only use attachments accessories specified by the manufacturer BO Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparat...

Page 2: ...NX 4x4 8x8 and 16x8 directly Even if the PC s default settings have been changed Solus NX 4x4 8x8 and 16x8 will attempt to establish communications by setting up appropriate routing table entries to reach devices with 169 254 x x addresses Connecting to Solus NX 4x4 8x8 and 16x8 from a host computer on the same LAN Both Solus NX 4x4 8x8 and 16x8 and the host computer require the following 3 items ...

Page 3: ... you wish to assign an IP address to and click the Properties button If you wish to assign Solus NX 4x4 8x8 or 16x8 a static IP address select Use the following IP address and enter the appropriate IP Address Subnet mask and Gateway Click OK when finished Now back in the locate hardware dialog ensure the Solus NX 4x4 8x8 or 16x8 device is selected and click Select Hardware Unit to use this Solus N...

Page 4: ...ited to scratches and dents unless failure has occurred due to a defect in materials or workmanship within the warranty period 7 Conditions caused by normal wear and tear or otherwise due to the normal aging of Symetrix products 8 Damage caused by use with another product 9 Product on which any serial number has been removed altered or defaced 10 Product that isn t sold by an authorized Symetrix D...

Reviews: