6. Pour the acid solution into the reservoir (
fi
g. 12-1).
The acid solution will now react with the lime scale.
7. Leave the solution to soak for a minimum of 10
minutes, until the foaming has stopped.
8. Use a brush to spread the acid over the level
electrodes during the soaking time (
fi
g. 12-2).
9. Put the plug in the socket again and turn on the
device so that the reservoir warms up.
10. Activate the MIXER cleaning programme (
fi
g. 12-3),
so that the acid solution leaves the water reservoir
via the MIXER VALVES. Place a drip tray under
both outlets (
fi
g. 12-4) and follow the instructions on
the
display.
11. Turn off the device and allow the reservoir to empty
completely using the tap (
fi
g. 12-1).
12. Turn on the device again; the reservoir will re
fi
ll with
clean water. Repeat instruction 10 one more time to
rinse the reservoir completely free of acid.
13. Turn on the device again; the reservoir will re
fi
ll with
clean water. Allow the water reservoir to heat up.
14. Activate the MIXER programme (
fi
g. 12-3), so that
valves and pipe systems are rinsed clean. Place the
measuring jug under the outlet (
fi
g. 12-4).
15. Repeat the above descaling procedure if lime scale
is still present in the reservoir.
16. Screw the lid back onto the reservoir and replace
the rear plate.
17. Clear the service parameter counter in the Service
Menu
2.6 Descale / fi lter /2.6.2 Reset service
counter.
18. The device is now ready for use again.
Fig. 12
1
2
3
4
5. COMPONENT
ACCESSIBILITY
Fig. 13
Main switch
Power relais
24V Supply
Ventilator
Ingredient motors
Dispensing valves
Display
Service panel
Interface
Water reservoir
Dry boil safety
Level / NTC
Drip tray full sensor
Inlet valve
Main PC board
Mixers
Cartridges
Splitter
Cartridge holders