54
08/2009 Rev. 0.4
S1000 All in One
S3000 All in One (MAXI)
S1000 / S3000 / S3000 MAXI
08/2009 Rev. 0.4
55
S1000 All in One
S3000 All in One (MAXI)
S1000 / S3000 / S3000 MAXI
Service menu continued…
Main item
Sub item
Item
Range
Set-
ting
Description
2.4 Settings
Language
English
Language choice display.
Ex factory setting English.
Dutch
German
French
Temperature
Temp. boiler
70-95°C
95°C
Boiler temperature
Hysteresis
2-10°C
2°C
Temperature drop, after which boiler
must reheat
Output block
70-90°C
78°C
Boiler temperature disables dispens-
ing. Display: [Out of order, boiler
heating]
Output release
70-90°C
85°C
Boiler temperature allows
dispensing again
Stand-by
60-80°C
60°C
Boiler temperature during stand-by
Extended Heating
0-5 sec
1 sec
To maintain the optimum boiler tem-
perature the heating element and
inlet valve switch on simultaneously.
Set the waste delay of the element
here after the inlet valve is closed.
Inlet valve
Heating
Display
Show clock
Yes/no
No
Show clock in display
Show date
Yes/no
No
Show date in display
Message text
Yes/no
No
Show message text (running text) in
display. Only shown if Display Date,
Clock or both are set to no. Mes-
sage text only programmable using
a future PC programme.
Use bleeper
Yes/no
Yes
Sound signal on or off
Fan time
0-300 sec.
60 s.
Duration of Fan speed 1 after
dispensing
Fan speed 1
40-100%
60%
Fan speed when resting
Fan speed 2
40-100%
100%
Fan speed during dispensing
Inlet valve
Heating
Service menu continued …..
Main item
Sub item
Item
Range
Set-
ting
Description
2.4 Settings
(continued…)
Coin system
G13
Coin channel 1
Coin channel 6
0-100,00 +
Token
€ 0,05
€ 0,10
€ 0,20
€ 0,50
€ 1,00
€ 2,00
Coin value setting for each channel.
€0.05-€2 respectively.
0.00=free
TOKEN=coffee token
Single vend
ja-nee
ja
Yes: any excess credit is not
retained for next drink. No: credit
retained for next drink.
Max coin accep.
€ 0,05-
100,00
€ 1,00
Coins larger than € 1.00 are rejected
and ejected through the return slot
of the coin mechanism. Adjust to the
highest recipe product price.
Point position
0-2
2
Decimal position in amount
Show credit
Yes/no
Yes
Show credit on the display
MDB
No MDB software available yet
I/0 Reset counter
Yes/no
No
Add Reset counters menu item to
the operator menu
I/0 Quick recipe
Yes/no
Yes
Add Quick recipe menu item to the
operator menu
Drip tray sign.
Yes/no
Yes
Turns off drip tray sensor software.
2.5 Reset counters
Rinse counters
Brewer counter?
Reset brewer spoelteller
Mixer counter?
Reset mixer spoelteller
Recipe counters
Recipe counter 1
Recipe counter 10
Reset recepttellers per recept.
Reset counter total
Reset totaal tellers
Reset all counters
Reset alle tellers ineens
2.6 Descale/fi lter
Service moment
0-50000
12500
After the Service Due setting has
been reached the Descale/
fi
lter
indicator will be displayed. See sec-
tion 5. Service
Service counter
?????
The number of beverages dis-
pensed is counted here. Check here
to see how far the machine is from
periodic maintenance (descaling
boiler or replacing water
fi
lter).
Reset serv. coun
After periodic maintenance has
been carried out (boiler descaled or
fi
lter replaced) the service counter
should be set to nil.