DOC06501_Revision
F
ATS-6501 Users Guide
81
Description:
Sets the antenna delay value for calibration and system on-time-point. The
system will accept scientific notation values as shown below. The example below has a
delay of 96.3nsec
Syntax
: antenna_delay [nt]
Command Example:
ATS-6501>antenna_delay 9.63E-8
Query:
ATS-6501>settings gps:antenna_delay
9.630000000000000e-08
Antenna Voltage:
Description:
Sets the DC Bias voltage level on the Antenna connector. Default is Zero.
The system will give the user an error message with the acceptable values [0,5,12] if the
operator attempts to enter an invalid DC voltage.
Syntax
: antenna_voltage [n]
Command Example:
ATS-6501>antenna_voltage 12
Query:
ATS-6501>
settings gps:antenna_voltage
0.000000000000
0V
5.000000000000
5VDC
1.200000000001
12VDC
Clear Alarms
Description:
Clears any latched alarm events from the alarm list and front panel. This
allows the operator to acknowledge a system alarm and clear it from the status message
(
status alarm
) and clear the front panel alarm light. If any additional alarms/events occur
the new alarm will be added to the list (
status alarm
) and the front panel alarm light will
illuminate. If the condition the
clear_alarms
command was issued for clears and returns,
the alarm will be displayed in status alarm and the front panel alarm light will come on.
Syntax
: clear_alarms
Command Example:
ATS-6501>clear_alarms
Latched alarms cleared
Config:
Description:
Displays the current system configuration settings. These settings are done
and the factory and cannot be changed by the user. They are for information only. Short-
cut for show config.