1
S100 User Guide – Rev. D – June 2005
5
2
5
3
•
Bandwidth consumption: Synchronizing the time over a WAN (wide area network)
consumes expensive bandwidth and degrades time accuracy (versus synchronizing
over a LAN).
•
Lost time: If your network synchronization relies on a time reference outside your
network, your network can be seriously compromised if the one connection to that
outside time reference is lost.
How the S100 Solves the Problem
The S100 provides your network with a single unbiased time reference based on one or more
external time references. Should all external time references become unavailable, the S100
uses its own high-performance crystal oscillator to keep time.
The S100, using its internal GPS receiver, operates as a Stratum 1 time server, with accuracy
to the nearest microsecond relative to UTC as maintained by the U.S. Naval Observatory,
one of the
National Measurement Institutes
(NMIs) in the U.S.
Time is distributed using the Network Time Protocol (NTP), and between multiple sites. The
result is that with the S100, network users can get time from within your firewall.
Full specifications are found in
“S100 Specifications” on page 119
.
National Measurement Institutes
The S100 synchronizes to UTC. This time standard is maintained by the International Bureau
of Weights and Measures (BIPM). By international agreement, each country’s National
Measurement Institute (NMI) maintains audit records of their synchronization with BIPM UTC,
thus providing verifiable sources of UTC within their countries. NMI clocks are disciplined to
be within nanoseconds of UTC time.
Country
Name of NMI
Abbreviation
United States
National Institute of Standards and Technology
NIST
France
Laboratoire Primaire du Temps et des Fréquences
LPTF
United Kingdom
National Physical Laboratory
NPL
Japan
Communications Research Laboratory
CRL
Summary of Contents for SyncServer S100
Page 2: ...2 S100 User Guide Rev D June 2005 1 ...
Page 20: ...12 S100 User Guide Rev D June 2005 1 SyncServer S100 ...
Page 60: ...52 S100 User Guide Rev D June 2005 SyncServer S100 ...
Page 94: ...86 S100 User Guide Rev D June 2005 SyncServer S100 ...
Page 108: ...100 S100 User Guide Rev D June 2005 SyncServer S100 Figure 5 43 Large Net NTP Configuration ...
Page 109: ...S100 User Guide Rev D June 2005 101 2 5 3 Figure 5 44 Large Net NTP Configuration 2 ...
Page 116: ...108 S100 User Guide Rev D June 2005 SyncServer S100 ...
Page 126: ...118 S100 User Guide Rev D June 2005 SyncServer S100 ...
Page 150: ...142 S100 User Guide Rev D June 2005 1 SyncServer S100 ...
Page 166: ...158 S100 User Guide Rev D June 2005 1 SyncServer S100 ...