4-66
TimeVault™ User’s Manual
6000-100Ch4.fm Rev. D
Chapter 4: Serial or Telnet I/O Functions
Extended Function Commands
4.4.10
F100 VER – Software Version Request
Use Version Request to obtain the software version number of the unit. The version
number is set at compile time, and cannot be changed. It may only be queried.
To query the version number send the following command:
F100
<SP>
VER
<Enter>
where:
F
=
ASCII character F
100
=
unit function number
<SP>
=
space
VER
=
specify Version Request command
<Enter>
=
input line terminator
An example of the response is:
>f100 VER
f100 VER
BOOTLOADER 182-9006v008
SOFTWARE 182-9007v008
FILE SYSTEM 182-9008v008
NVRAM VER 2
4.4.11
F100 T – Current Time Source Request
Use Current Time Source Request to know which time source TimeVault is currently
using.
To query the current time source, send the following command:
F100
<SP>
T
<Enter>
where:
F
=
ASCII character F
100
=
TimeVault function number
<SP>
=
space
T
=
specify Current Time Source Request command
<Enter>
=
input line terminator
An example of the response is:
F100 T GPS <CR><LF>