100
TimeProvider 500 2.0 User’s Guide
098-00172-000 Revision A – December, 2009
Chapter 4 CLI Commands
Set Alarm Commands
Response
:
Alarm level 9 set to minor
set alarm-config proxy
This is a new command for version 2.0. The number of alarms has increased from
14 to 19 in version 2.0.
This command enables or disables the capability for an alarm to generate an
autonomous message via PTP management (see
when the alarm has alarm or event activity. The
alarm_num
option
selects which
alarm will have the proxy option. This command enables a receiving device to act
on behalf of the TimeProvider 500. This would allow the receiving device to either
handle the alarm or forward it via an SNMP trap.
Syntax:
set alarm-config proxy { alarm
alarm_num
} { enable | disable }
Range:
alarm_num
= [0, 1, … , N], N currently = 19
Default:
See
for default severities.
Example:
Sets all alarms to minor severity.
set alarm-config proxy alarm 9 enable
Response
:
Alarm 9 proxy is enabled
set alarm-config state
The number of alarms has increased from 14 to 19 in version 2.0.
This command enables or disables the reporting of selected alarms.
alarm_num
allows you to apply settings to individual alarms.
Syntax:
set alarm-config state {alarm alarm_num} {enable | disable}
Range
:
alarm_num
= [0, 1, … , N], N currently = 19
Default:
The default setting for all alarms is
enable
.
Example:
Disables alarm number 3
set alarm-config state alarm 3 disable
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...