show status-list
This command provides a summary of current TimeProvider 500 performance
status via the PTP management command
Syntax:
TP-500> show status-list
Response:
Current time is : 21:52:17 11/09/2009
Current FLL State : Normal FLL
FLL State Duration (minutes) : 2840
Forward Flow Weight (%) : 1.00
Forward Flow Transient-free (out of 900 s) : 900
Forward Flow Transient-free (out of 3600 s) : 3600
Forward Flow Percentile Clustering (%) : 99.8
Forward Flow Operational Min TDEV (ns) : 2.7
Forward Flow Operational MAFE (ppb) : 0.01
Forward Flow Min Cluster Width (ns) : 100.0
Forward Flow Mode Width (ns) : 100.0
Reverse Flow Weight (%) : 99.00
Reverse Flow Transient-free (out of 900 s) : 900
Reverse Flow Transient-free (out of 3600 s) : 3600
Reverse Flow Percentile Clustering (%) : 99.8
Reverse Flow Operational Min TDEV (ns) : 1.8
Reverse Flow Operational MAFE (ppb) : 0.01
Reverse Flow Min Cluster Width (ns) : 100.0
Reverse Flow Mode Width (ns) : 200.0
Correction Frequency (ppb) : -10.12
Phase correction (ppb) : 0.00
Output TDEV Estimate (ns) : 1.80
Output MDEV Estimate (ppb) : 0.00
Residual phase error (ns) : 2377.13
Minimal RTD (us) : 12.57
Operational Temperature Max (deg C) : 41.06
Operational Temperature Min (deg C) : 40.88
Operational Temperature Avg (deg C) : 41.01
5 Minute Temperature Stability (mdeg C) : 55.37
60 Minute Temperature Stability (mdeg C) : 166.04
Timing Packet Rate GM1 (pkts/s) : 0
Timing Packet Rate GM2 (pkts/s) : 64
Timing Packet Rate Delay (pkts/s) : 64
Observation Interval (min) : 1
IPDV Threshold (usec) : 50.000
Pacing Factor for Jitter Computation : 16
Forward IPDV % Below Threshold : 100.0
Forward Maximum IPDV (usec) : 0.187
Forward InterPkt Jitter (usec) : 0.036
Reverse IPDV % Below Threshold : 100.0
Reverse Maximum IPDV (usec) : 0.168
Reverse InterPkt Jitter (usec) : 0.052
Reference : GM2
GM1 Flow State : Waiting for GM to respond to signaling
GM2 Flow State : Normal
GM1 Clock id : 00:00:00:00:00:00:00:00
GM2 Clock id : 00:B0:AE:FF:FE:01:31:65
Last Firmware Upgrade status : Upgrade succeeded
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...